2. FIRST START-UP
SUPPOR
T
CENTRE
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P10
DOMESTIC FAN MINIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET THE
FAN MINIMUM SPEED IN DOMESTIC PHASE, THAT
CORRESPONDS TO THE MINIMUM BURNER POWER
DURING A REQUEST TO OPERATE IN DOMESTIC
MODE.
THE VALUE IS PRE-SET BASED ON THE SET POWER
(SEE PARAMETER P00) AND ON THE GAS TYPE (SEE
PARAMETER P02).
SEE CHAPTER
‘
H
E
A
T
C A P A C I T Y
D I A G R A M
(KW) –
ELECTRIC FAN
F R E Q U E N C Y
(HZ)’
THE VALUE IS EXPRESSED IN HERTZ
(1HZ = 30 RPM)
P11
DOMESTIC FAN MAXIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET THE
FAN MAXIMUM SPEED IN DOMESTIC PHASE, THAT
CORRESPONDS TO THE MAXIMUM BURNER POWER
DURING A REQUEST TO OPERATE IN DOMESTIC
MODE.
THE VALUE IS PRE-SET BASED ON THE SET POWER
(SEE PARAMETER P00) AND ON THE GAS TYPE (SEE
PARAMETER P02).
SEE CHAPTER
‘
H
E
A
T
C A P A C I T Y
D I A G R A M
(KW) –
ELECTRIC FAN
F R E Q U E N C Y
(HZ)’
THE VALUE IS EXPRESSED IN HERTZ
(1HZ = 30 RPM)
P12
HEATING FAN MINIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET THE
FAN MINIMUM SPEED IN HEATING PHASE, THAT
CORRESPONDS TO THE MINIMUM BURNER POWER
DURING A REQUEST TO OPERATE IN HEATING MODE.
THE VALUE IS PRE-SET BASED ON THE SET POWER
(SEE PARAMETER P00) AND ON THE GAS TYPE (SEE
PARAMETER P02).
SEE CHAPTER
‘
H
E
A
T
C A P A C I T Y
D I A G R A M
(KW) –
ELECTRIC FAN
F R E Q U E N C Y
(HZ)’
THE VALUE IS EXPRESSED IN HERTZ
(1HZ = 30 RPM)
P13
HEATING FAN MAXIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET THE
FAN MAXIMUM SPEED IN HEATING PHASE, THAT
CORRESPONDS TO THE MAXIMUM BURNER POWER
DURING A REQUEST TO OPERATE IN HEATING MODE.
THE VALUE IS PRE-SET BASED ON THE SET POWER
(SEE PARAMETER P00) AND ON THE GAS TYPE (SEE
PARAMETER P02).
SEE CHAPTER
‘
H
E
A
T
C A P A C I T Y
D I A G R A M
(KW) –
ELECTRIC FAN
F R E Q U E N C Y
(HZ)’
THE VALUE IS EXPRESSED IN HERTZ
(1HZ = 30 RPM)