2. FIRST START-UP
SUPPOR
T
CENTRE
2.1.5. MIAB3013 PARAMETERS TABLE
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P00
BOILER MODEL SELECTION
00 - 0
4
00 = 24 kW
01 = 25 kW (HEAT.) / 28 kW (DOMESTIC)
02 = 34 kW
03 = 50 kW
04 = 24 kW - WITH HONEYWELL GAS VALVE
P01
BOILER TYPE SELECTION
00 - 03
00 = ISTANTANEOUS WITH INTEGRATED HEAT
EXCHANGER FOR D.H.W. SIDE
01 = ISTANTANEOUS WITH D.H.W. PLATES
EXCHANGER
02 = ACCUMULATION
03 = HEATING ONLY
P02
GAS TYPE SELECTION
ATTENTION:
READ THE INSTRUCTION IN CHAPTER ‘GAS
TRANSFORMATION’ BEFORE CHANGING THIS
PARAMETER.
00 - 01
00 = METHANE
01 = LPG
P03
SETTING THE HEATING TEMPERATURE
IN CASE THE BOILER IS INSTALLED AS PART OF A
LOW TEMPERATURE CIRCUIT, PLEASE INSTALL
A SAFETY THERMOSTAT ON THE HEATING FLOW,
WHICH CAN STOP THE BOILER ACTIVITY IN CASE
OF HIGH HEATING FLOW TEMPERATURE. THE
COMPANY ASSUMES NO LIABILITY FOR DAMAGE
CAUSED TO PERSONS OR FOR FAILURE TO COMPLY
WITH THESE INSTRUCTIONS.
00 - 01
00 = STANDARD (30-80 °C)
(SET BY DEFAULT)
01 = REDUCED (25-45 °C) FOR FLOOR
SYSTEMS