2. FIRST START-UP
SUPPOR
T
CENTRE
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P10
FAN MINIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET THE FAN MINIMUM
SPEED THAT CORRESPONDS TO THE MINIMUM POWER OF THE
BURNER.
THE VALUE IS PRE-SET BASED ON THE SET POWER (SEE
PARAMETER P00) AND ON THE GAS TYPE (SEE PARAMETER P02).
(CHANGE THE PARAMETER VALUE ON BOTH CONTROL PANELS,
MASTER AND SLAVE, PLEASE SEE CHAPTER "PARAMETER ACCESS
AND PROGRAMMING").
38 - VALUE
SET FOR
PARAMETER
P11
THE VALUE IS EXPRESSED IN
HERTZ
(1HZ = 30 RPM)
P11
FAN MAXIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET THE FAN MAXIMUM
SPEED THAT CORRESPONDS TO THE MAXIMUM POWER OF THE
BURNER. THE VALUE IS PRE-SET BASED ON THE SET POWER (SEE
PARAMETER P00) AND ON THE GAS TYPE (SEE PARAMETER P02).
(CHANGE THE PARAMETER VALUE ON BOTH CONTROL PANELS,
MASTER AND SLAVE, PLEASE SEE CHAPTER "PARAMETER ACCESS
AND PROGRAMMING").
VALUE
SET FOR
PARAMETER
P10 - 290
THE VALUE IS EXPRESSED IN
HERTZ
(1HZ = 30 RPM)
P12
HEATING FAN MINIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET THE FAN MINIMUM
SPEED IN HEATING PHASE, THAT CORRESPONDS TO THE
MINIMUM BURNER POWER DURING A REQUEST TO OPERATE IN
HEATING MODE. [SEE CHAPTER ‘HEAT CAPACITY DIAGRAM (KW) –
ELECTRIC FAN FREQUENCY (HZ)’].
THE VALUE IS PRE-SET BASED ON THE SET POWER (SEE
PARAMETER P00) AND ON THE GAS TYPE (SEE PARAMETER P02).
(CHANGE THE PARAMETER VALUE ON BOTH CONTROL PANELS,
MASTER AND SLAVE, PLEASE SEE CHAPTER "PARAMETER ACCESS
AND PROGRAMMING").
38 - VALUE
SET FOR
PARAMETER
P13
THE VALUE IS EXPRESSED IN
HERTZ
(1HZ = 30 RPM)
P13
HEATING FAN MAXIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET THE FAN MAXIMUM
SPEED IN HEATING PHASE, THAT CORRESPONDS TO THE
MAXIMUM BURNER POWER DURING A REQUEST TO OPERATE IN
HEATING MODE [SEE CHAPTER ‘HEAT CAPACITY DIAGRAM (KW) –
ELECTRIC FAN FREQUENCY (HZ)’].
THE VALUE IS PRE-SET BASED ON THE SET POWER (SEE
PARAMETER P00) AND ON THE GAS TYPE (SEE PARAMETER P02).
(CHANGE THE PARAMETER VALUE ON BOTH CONTROL PANELS,
MASTER AND SLAVE, PLEASE SEE CHAPTER "PARAMETER ACCESS
AND PROGRAMMING").
VALUE
SET FOR
PARAMETER
P12 - 290
THE VALUE IS EXPRESSED IN
HERTZ
(1HZ = 30 RPM)