1. INSTALLATION
INST
ALLER
REMOTE BOILER SYSTEM - BOILER PROBE AND DIVERTER VALVE CONNECTION
- clamp M9 - boiler probe: insert the boiler probe cable inside the panel inserting the terminals 35 and 34.
It is not necessary to follow an order of wires.
- clamp M4 - diverter valve: connect the motor cable of the diverter valve by means of the molex clamp.
Insert the cable inside the tool panel and connect the terminals of the cable to the clamp M4 paying
attention to the combinations: blue – clamp no. 9; brown – clamp no. 8; black – clamp no. 10.
11
10
9
8
7
12
13
14
15
16
17
M12
M9
M7
M5
M2
M4
M8
M10
M15
M16
1
2
3
4
57
61
60
59
58
44 43 42 41 40 39 38
37 36 35 34 33 32
31 30 29 28
27 26
62
63
64
65
66
67
68
51
52
53
54
55
56
5
6
M13
M14
fig. 1
RECIRCULATION
HOT WATER
COLD WATER
REMOTE BOILER
black
black
max. 8 m
brown
blue
black
DOMESTIC CIRCUIT PROBE