All field wiring to the HL2-DS series heater must be done in accordance with the national, state,
provincial, local codes, and the guidelines in this manual. In the United States, refer to the most current
revisions to the Electrical Code ANSI/NFPA 70. The unit must be electrically grounded according to
these codes.
Field Wiring Supply Voltage
Before proceeding with electrical connections, ensure that the supply voltage, frequency, phase, and
current capacity meet the requirements specified on the rating plate. A dedicated line voltage supply
with properly sized wire should run directly from the main electrical panel to the heater. The power to
the unit must be protected with a circuit breaker appropriate for the load. The unit must be electrically
grounded in accordance with local codes, or in their absence, with the latest edition of the National
Electrical Code, ANSI / NFPA 70 and/or the Canadian Electrical Code CSA C22.1, latest edition.
The heater comes equipped with a supply cord to connect the main power supply. It is located at the
rear of the heater’s burner box, and utilizes a grounding prong. This plug must be connected into an
appropriate outlet receptacle that is properly installed and grounded in accordance to local codes
and ordinances.
The grounding receptacle must be installed within 5 feet of the heater’s service panel, and located in
the space occupied by the appliance. When plugging in the heater, make sure the supply cord is
protected from damage, and keep all cords away from the heater’s surfaces and out of the clearance
to combustible zones (see page 9). When routing the electrical supply for the unit, ensure that it does
not interfere or obstruct the heater’s service panel. Keep any electrical supply cord away from any
heated surfaces.
WARNING
!
Incorrect or improper wiring may result in shock, injury, or death. Field wiring to the heater
must be connected and grounded in accordance with national, state, provincial, local
codes, and to the guidelines in this manual. Refer to the most current revisions to the
ANSI/NFPA 70 Standard.
The power supply to the heater must be /- 5% of the voltage rating as indicated on the
rating plate of the appliance. If input power does not meet these specifications, contact your utility
company.
CAUTION
!
WARNING
!
Electric Shock Hazard
Do not force the three-prong plug into the grounded outlet, modify the plug, or use an
adapter. Never operate this appliance if the cord or plug is damaged.