Do  not  use  the  product  in  rooms  saturated  with  explosive  gas,  vapours 
generated by solvents or paints or flammable vapours/gas. 

 

If the cable and/or plug are damaged, do not repair them yourself but take 
the  product  to  the  technical  service  or  a  qualified  repair  centre  and  have 
them  repaired  by  specialised  personnel  in  order  to  avoid  any  risk  of 
damage. 

 

Always position the product so that the plug is immediately accessible.

 

 

Never position this appliance immediately underneath a power socket.

 

 

Do not insert objects or paper into the radiator.

 

 

2.  Your product 

 

Other than the heater you have chosen the package includes (picture 1): 

-

 

N° 1 metal brackets for wall mounting (fixed to the radiator); 

-

 

N° 4 nylon plug expansion 8x50mm; 

-

 

N° 4 5x60mm cross head screws to fix wall brackets; 

 

Refer to your dealer is something is broken or missing. 

 

3.  Safe positioning 

 

Only use the product in its horizontal position; 

 

This  product  is  fitted  with  a  double  electrical  insulation  circuit  (class  II)  and  therefore  does  not  require  an  earth 
connection; 

 

Always make observe the minimum distances from walls, furniture and/or objects, as indicated in picture 2. 

 

 

Never install the product on a surface made from wood or synthetic material. 

 

This  product  is  water  resistant  to  IP24.  It  may  therefore  be  used  in  bathrooms  or  other  areas  subject  to  humidity 
provided it is never installed within the perimeter of bathtubs or showers (Volume 1 of figure 2).

 

 

Do not install the radiator in a draft that could disturb its regulation. 

 

4.  Installation 

 

Remove the wall-mounting bracket fixed to the back of the radiator, by releasing first the 2 upper springs and then the 
2 lower springs as shown in figure 4. 

 

Rest  the  bracket  on  the  floor  to  use  it  as  a  template  to  mark  the  points  a  which  the  two  lower  fixing  holes  are  to  be 
made (figure 5A).   

 

Lift the bracket until its lower fixing points coincide with the marks made on the wall before, and use a pencil to mark 
the position of the two upper fixing points (figure 5B).  

 

Drill the 4 holes at the points marked previously, and insert the plastic anchors (figure 6).  

 

Fix the bracket to the wall using the 4 screws supplied (figure 7).  

 

Hook  the  radiator  to  the  bracket  starting  with  the  2  lower  fixing  points,  and  then  click  the  2  upper  fixing  points  into 
position (figure 8).  

 

Should you have to remove the radiator from the bracket at a later stage, we recommend releasing the lower two fixing 
points first and then the upper fixings.  

 

5.  Electrical connections 

 

The product must be powered at a voltage of 230V AC 50Hz. 

 

The product must be supplied with a cable and plug or with a cable for installation. If a product with plug is installed in 
France, connect it to the mains power supply by cutting off the plug and using a suitable connection box.

 

 

If the product is supplied with a cable for installation without plug, connect it to the mains power supply using a 3-wire 
cable (Brown=Live, Blue=Neutral, Black=Pilot wire) and a connection box. 

If  you  do not wish to use the pilot wire 

functions,  just  connect  the  phase  and  the  neutral  wires:  the  product  will  work  correctly  even  without  the 
external programmer

.

 

 

In bathrooms, kitchens or other humid areas, install the connection terminal at least 25cm off the floor. 

 

The  electrical  connection  to  the  mains  power  supply  must  also  include  a  2-pole  switch  with  a  minimum  contact 
aperture of 3mm. As a priority, always abide you national wiring rules. 

 

It is forbidden to connect the appliance to the earth circuit. 

DO NOT CONNECT THE PILOT WIRE (BLACK) TO THE 

EARTH CIRCUIT

.

 

Содержание KLIMA Series

Страница 1: ...e consultazioni GB Please retain these instructions in a safe place for future reference FR Conserver cette notice pour toute consultation ult rieure RO Pastrati instructiunile pentru consultari ulter...

Страница 2: ...2 n 1 n 1 n 4 5x60mm n 4 8x50mm 1 4 mm 2 3 4 min 15cm min 15cm min 15cm min 50cm min 15cm 1 1 3 3 2 2 4 4...

Страница 3: ...3 6 8 7 click 5 click A B...

Страница 4: ...4 9 3m 1m 4m 3m...

Страница 5: ...r mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children...

Страница 6: ...wn in figure 4 Rest the bracket on the floor to use it as a template to mark the points a which the two lower fixing holes are to be made figure 5A Lift the bracket until its lower fixing points coinc...

Страница 7: ...unction controlled by the key pushed 6 2 2 Switching the radiator on and off The power supply to the radiator is controlled by a two pole electromechanical switch G located on the right side of the ra...

Страница 8: ...ode to Comfort mode Icon Description When used Comfort When at home The radiator works to maintain the comfort temperature set Eco When you are away from home for short periods from 2 to 48 hours or y...

Страница 9: ...mes by going to Comfort mode first using the M key and then selecting the value required using the and keys Please note In Pilot Wire mode the Eco temperature is always equal to the Comfort temperatur...

Страница 10: ...ing saved the date and time this setting procedure will be activated automatically 6 2 6 Customizing P1 Program Program P1 may be modified to suit the users needs Modification of P1 gives the user the...

Страница 11: ...ation involves the period of time between 23 00 and 00 00 Having modified the temperature for each of the 23 hours of Day 1 press further button to enter the modification mode of Day 2 Press button to...

Страница 12: ...esult will be the cancellation of the display modification procedure and will restore back the factory default settings During the programmation process the heating elements will automatically switch...

Страница 13: ...ay directly Day 3 Wednesday Repeat the procedure previously described until D 6 appears on the display Since we don t want to modify Day 6 and 7 we can exit the Program settings mode holding F and pre...

Страница 14: ...e by pushing the or keys respectively Activation is indicated by the relevant icon that switches on on the display Daily consumption This function makes it possible to view the power the radiator has...

Страница 15: ...aving Thanks to this function which can only be activated in Comfort mode the radiator continuously monitors the room and if no people are detected it reduces the comfort temperature set as follows Pe...

Страница 16: ...er being interrupted for more than 30 minutes when it is switched on Stand by mode is not set as normally happens by Comfort mode starts immediately The comfort temperature is as set before the power...

Страница 17: ...raughts The temperature in the room differs from the temperature set Having waiter for the ambient temperature to stabilise for at least 4 hours you may have to compensate for any differences between...

Страница 18: ...In standby mode elSB 0 00025 kW Two or more manual stages no room temperature control no with mechanic thermostat room temperature control no with electronic room temperature control no electronic roo...

Отзывы: