EN - Information requirements for electric local space heaters

 

Model identifier(s): KLIMA 

Item 

Symbol 

Value 

Unit 

 

Item 

Unit 

Heat output

 

 

Type of heat input, for electric storage local space heaters only (select one)

 

Nominal heat output 

P

nom

 

(*) see 

Table 1 

kW 

 

manual heat charge control, with integrated thermostat 

no 

Minimum heat output 
(indicative) 

P

min

 

(*) see 

Table 1 

kW 

 

manual heat charge control with room and/or outdoor temperature 
feedback 

no 

Maximum continuous 
heat output 

P

max,c

 

(*) see 

Table 1 

kW 

 

electronic heat charge control with room and/or outdoor temperature 
feedback 

no 

Auxiliary electricity 
consumption

 

 

 

 

 

fan assisted heat output 

no 

At nominal heat 
output 

el

max

 

(*) see 

Table 1 

kW 

 

Type of heat output/room temperature control (select one)

 

 

At minimum heat 
output 

el

min

 

(*) see 

Table 1 

kW 

 

single stage heat output and no room temperature control 

no 

In standby mode 

el

SB

 

0,00025 

kW 

 

Two or more manual stages, no room temperature control 

no 

 

 

 

 

 

with mechanic thermostat room temperature control 

no 

 

 

 

 

 

with electronic room temperature control 

no 

 

 

 

 

 

electronic room temperature control plus day timer 

no 

 

 

 

 

 

electronic room temperature control plus week timer 

yes 

 

 

 

 

 

Other control options (multiple selections possible)

 

 

 

 

 

 

 

room temperature control, with presence detection 

yes 

 

 

 

 

 

room temperature control, with open window detection 

yes 

 

 

 

 

 

with distance control option 

no 

 

 

 

 

 

with adaptive start control 

no 

 

 

 

 

 

with working time limitation 

no 

 

 

 

 

 

with black bulb sensor 

no 

Contact details 

Ermete Giudici S.p.A. - via L. da Vinci 27 - 20090 Segrate (MI) Italia 

 

Table 1 

 

KLIMA 7 
KLIMA 7 AS 

KLIMA 10 

KLIMA 15 

KLIMA 20 

Heat output

 

 

 

 

 

 

Nominal heat output 

P

nom

 

0,750 

1,000 

1,500 

2,000 

Minimum heat output (indicative) 

P

min

 

0,075 

0,113 

0,150 

0,188 

Maximum continuous heat output 

P

max,c

 

0,750 

1,000 

1,500 

2,000 

Auxiliary electricity consumption

 

 

 

 

 

 

At nominal heat output 

el

max

 

0,750 

1,000 

1,500 

2,000 

At minimum heat output 

el

min

 

0,075 

0,113 

0,150 

0,188 

Содержание KLIMA Series

Страница 1: ...e consultazioni GB Please retain these instructions in a safe place for future reference FR Conserver cette notice pour toute consultation ult rieure RO Pastrati instructiunile pentru consultari ulter...

Страница 2: ...2 n 1 n 1 n 4 5x60mm n 4 8x50mm 1 4 mm 2 3 4 min 15cm min 15cm min 15cm min 50cm min 15cm 1 1 3 3 2 2 4 4...

Страница 3: ...3 6 8 7 click 5 click A B...

Страница 4: ...4 9 3m 1m 4m 3m...

Страница 5: ...r mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children...

Страница 6: ...wn in figure 4 Rest the bracket on the floor to use it as a template to mark the points a which the two lower fixing holes are to be made figure 5A Lift the bracket until its lower fixing points coinc...

Страница 7: ...unction controlled by the key pushed 6 2 2 Switching the radiator on and off The power supply to the radiator is controlled by a two pole electromechanical switch G located on the right side of the ra...

Страница 8: ...ode to Comfort mode Icon Description When used Comfort When at home The radiator works to maintain the comfort temperature set Eco When you are away from home for short periods from 2 to 48 hours or y...

Страница 9: ...mes by going to Comfort mode first using the M key and then selecting the value required using the and keys Please note In Pilot Wire mode the Eco temperature is always equal to the Comfort temperatur...

Страница 10: ...ing saved the date and time this setting procedure will be activated automatically 6 2 6 Customizing P1 Program Program P1 may be modified to suit the users needs Modification of P1 gives the user the...

Страница 11: ...ation involves the period of time between 23 00 and 00 00 Having modified the temperature for each of the 23 hours of Day 1 press further button to enter the modification mode of Day 2 Press button to...

Страница 12: ...esult will be the cancellation of the display modification procedure and will restore back the factory default settings During the programmation process the heating elements will automatically switch...

Страница 13: ...ay directly Day 3 Wednesday Repeat the procedure previously described until D 6 appears on the display Since we don t want to modify Day 6 and 7 we can exit the Program settings mode holding F and pre...

Страница 14: ...e by pushing the or keys respectively Activation is indicated by the relevant icon that switches on on the display Daily consumption This function makes it possible to view the power the radiator has...

Страница 15: ...aving Thanks to this function which can only be activated in Comfort mode the radiator continuously monitors the room and if no people are detected it reduces the comfort temperature set as follows Pe...

Страница 16: ...er being interrupted for more than 30 minutes when it is switched on Stand by mode is not set as normally happens by Comfort mode starts immediately The comfort temperature is as set before the power...

Страница 17: ...raughts The temperature in the room differs from the temperature set Having waiter for the ambient temperature to stabilise for at least 4 hours you may have to compensate for any differences between...

Страница 18: ...In standby mode elSB 0 00025 kW Two or more manual stages no room temperature control no with mechanic thermostat room temperature control no with electronic room temperature control no electronic roo...

Отзывы: