Reinstating default settings 
 

 

To  reinstate  all  the  radiator's  parameters 
to  the  default  settings  set  by  the 
manufacturer  hold  at  least  for  3sec  the 
"+" key down. 
 

 

 

Presence sensor   

 
This  function  allows  the  radiator  to  pick 
up  whether  or  not  people  are  in  the 
space,  and  automatically  regulate  the 
heating level, in order to optimise comfort 
and energy saving.  
 
For further details see paragraph 6.3.1.  

 

Switching  the  function  (ON)  or  (OFF)  is 
done  by  pushing  the  “+”  or  “-“  keys 
respectively.  
 

 

 
Activation  is  indicated  by  the  relevant 

icon that switches on, on the display 

 

Window open sensor  

 
This  function  makes  it  possible  to  detect 
an  open  window  and  automatically 
activate the anti-freeze operating mode.  
 
For further details see paragraph 6.3.2. 

 

Switching  the  function  (ON)  or  (OFF)  is 
done  by  pushing  the  “+”  or  “-“  keys 
respectively. 
 

 

 
Activation  is  indicated  by  the  relevant 

icon that switches on, on the display 

 

Daily consumption  

 
This  function  makes  it  possible  to  view 
the  power  the  radiator  has  consumed 
over the previous 24 hours. 

 

If  the  consumption  indication  is  flashing, 
this means that the data saved relates to 
a period of less than 24 hours.  
 

Please  note

:  The  display  shows  the 

estimated  consumption,  which  may  differ 
from  that  measured  by  specific  meters, 
suitable for the purpose.   

Weekly consumption  

 
This  function  makes  it  possible  to  view 
the  power  the  radiator  has  consumed 
over the previous 7 days.

 

 

If  the  consumption  indication  is  flashing, 
this means that the data saved relates to 
a period of less than 7 days. 
 

Please  note

:  The  display  shows  the 

estimated  consumption,  which  may  differ 
from  that  measured  by  specific  meters, 
suitable for the purpose. 

Displaying the ambient temperature 

 

The 

display 

shows 

the 

ambient 

temperature measured by the radiator. 

Содержание KLIMA Series

Страница 1: ...e consultazioni GB Please retain these instructions in a safe place for future reference FR Conserver cette notice pour toute consultation ult rieure RO Pastrati instructiunile pentru consultari ulter...

Страница 2: ...2 n 1 n 1 n 4 5x60mm n 4 8x50mm 1 4 mm 2 3 4 min 15cm min 15cm min 15cm min 50cm min 15cm 1 1 3 3 2 2 4 4...

Страница 3: ...3 6 8 7 click 5 click A B...

Страница 4: ...4 9 3m 1m 4m 3m...

Страница 5: ...r mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children...

Страница 6: ...wn in figure 4 Rest the bracket on the floor to use it as a template to mark the points a which the two lower fixing holes are to be made figure 5A Lift the bracket until its lower fixing points coinc...

Страница 7: ...unction controlled by the key pushed 6 2 2 Switching the radiator on and off The power supply to the radiator is controlled by a two pole electromechanical switch G located on the right side of the ra...

Страница 8: ...ode to Comfort mode Icon Description When used Comfort When at home The radiator works to maintain the comfort temperature set Eco When you are away from home for short periods from 2 to 48 hours or y...

Страница 9: ...mes by going to Comfort mode first using the M key and then selecting the value required using the and keys Please note In Pilot Wire mode the Eco temperature is always equal to the Comfort temperatur...

Страница 10: ...ing saved the date and time this setting procedure will be activated automatically 6 2 6 Customizing P1 Program Program P1 may be modified to suit the users needs Modification of P1 gives the user the...

Страница 11: ...ation involves the period of time between 23 00 and 00 00 Having modified the temperature for each of the 23 hours of Day 1 press further button to enter the modification mode of Day 2 Press button to...

Страница 12: ...esult will be the cancellation of the display modification procedure and will restore back the factory default settings During the programmation process the heating elements will automatically switch...

Страница 13: ...ay directly Day 3 Wednesday Repeat the procedure previously described until D 6 appears on the display Since we don t want to modify Day 6 and 7 we can exit the Program settings mode holding F and pre...

Страница 14: ...e by pushing the or keys respectively Activation is indicated by the relevant icon that switches on on the display Daily consumption This function makes it possible to view the power the radiator has...

Страница 15: ...aving Thanks to this function which can only be activated in Comfort mode the radiator continuously monitors the room and if no people are detected it reduces the comfort temperature set as follows Pe...

Страница 16: ...er being interrupted for more than 30 minutes when it is switched on Stand by mode is not set as normally happens by Comfort mode starts immediately The comfort temperature is as set before the power...

Страница 17: ...raughts The temperature in the room differs from the temperature set Having waiter for the ambient temperature to stabilise for at least 4 hours you may have to compensate for any differences between...

Страница 18: ...In standby mode elSB 0 00025 kW Two or more manual stages no room temperature control no with mechanic thermostat room temperature control no with electronic room temperature control no electronic roo...

Отзывы: