background image

Important installation instructions

Before installation check...:

  ...whether your door operator is suitable for the type  

  of garage door and the garage door height. 

  ...that the door is in a perfect mechanical state. The  

  door must be smooth running and be balanced.  

  Check whether it opens and closes properly; 
  Open the door approx. 1 metre and let go. A  

  balanced door should now remain in this position. 

   If not, have your door adjusted by a specialist  

 company.

 The door operation must not be hindered by in- 

  correctly adjusted springs or by incorrectly func- 

  tioning door suspensions or door constructions.

Before installing the drive..., 

 ....remove all unnecessary ropes or chains and disable  

  any equipment, such as locks, not needed for powered  
 operation.

STOP

During installation there is a danger of injury 

due to the unsecured door falling suddenly.

 During the installation work, ensure that there are  

  no persons in the swivelling area of the garage door. 

Important instructions for a safe installation. 

Follow all installation instructions carefully. 
An incorrect installation can lead to serious 

injuries.

Faulty installation can result in serious ac-

cidents and injuries.

  Fit the actuator for the emergency release at a height  

  of less than 1.8 metres.

  Use only the enclosed mounting materials and only  

  original spare parts and original accessories.

 Any existing door locking devices already fitted to  

  the door may hinder the correct functioning of the  

  door and must therefore be removed. 

 Movable parts of the garage door must not extend  

  into public footpaths or cycle paths.

 Poor lighting hinders the installation work and can  

  result in injuries. Ensure that there is adequate  

  lighting during installation work. 

 It is possible that during the installation work, you  

  may not be able to open the door for a short period  

  of time.

  This drive is not to be used with doors having openings  

  exceeding 50 mm in diameter or having edges or  

  protruding parts a person could grip or stand on.

  Permanently fix the label concerning the manual release  

  adjacent to its actuating member.

 Attach all labels so that they are clearly legible.

 The manufacturer is not liable for damage which  

  occurs due to incorrect or non-compliant use (see  

  warranty conditions).

12

EN

Содержание RolloPort S2

Страница 1: ...Item no 4201 70 61 4202 70 61 VBD 543 02 01 23 EN Garage door drive RolloPort S2 Translation of the Original Operating and Assembly Manual...

Страница 2: ...ric shock This sign warns of danger when working on electrical connections components etc It requires that safety precautions be taken to protect the health and life of the person concerned This conce...

Страница 3: ...allation of the fixing bracket 5 at the door operator head 7 18 C Installation of the door bracket 8 19 D Installation of the middle support clip 13 20 E Installation on the ceiling with perforated br...

Страница 4: ...r including lighting 2 Hand transmitter 3 LED 4 1st hand transmitter button 5 2nd hand transmitter button 6 Set button S 7 Display 8 Button for adjustment 9 Button for adjustment 10 Programming button...

Страница 5: ...15 mm 1 x Screw 6 x 80 mm with hexagon nut 1 x Bolt 8 x 20 mm 1 x Securing bolt 2 x 20 mm 4 x Screw 8 x 20 mm with hexagon nut and plain washer 6 x Wall plug 10 mm 6 x Hexagon head screw 8 x 60 mm 1 x...

Страница 6: ...stationary All work performed on electrical equipment is associated with a risk of electric shock and electrocution Have all work on electrical equipment and on the door operator carried out by a qua...

Страница 7: ...der proper operation A220 240V 50 60Hzpowersupplymustbeavail able at the place of installation Comply with all maintenance intervals Proper use also includes the regular inspection of the door and its...

Страница 8: ...y existing safety equip ment which deviate from the measures described in this manual Such alterations endanger the operating safety The garage door operator must not be used in commercial establishme...

Страница 9: ...mergency release cable in the case of power failure Automatic closing function The automatic closing time of the door can be set from 30 to 240 seconds refer to page 25 26 2000 cycle alarm When the op...

Страница 10: ...nal open position Place a 50 mm high object e g a wooden block in the direction of travel of the door Close the door by actuating the hand trans mitter If the door hits an obstruction when closing the...

Страница 11: ...egular checks of wearing parts There is a risk of injury due to defective or worn components Check the system therefore regularly for signs of wear damage or lack of balance of the door Do not use the...

Страница 12: ...structions carefully An incorrect installation can lead to serious injuries Faulty installation can result in serious ac cidents and injuries Fit the actuator for the emergency release at a height of...

Страница 13: ...cks Remove all vertical and horizontal door locks and catches IMPORTANT Keep the old door locks in a safe place In the event that you should remove the garage door operator you will have to fit these...

Страница 14: ...ong Determine the distance between the top edge of the door and the ceiling Close the door slowly and measure the distance between the top edge of the door and the ceiling NOTE The minimum distance sh...

Страница 15: ...ive Tension the drive chain 1 Connector 1 Fixing plates Connector 2 1 2 3 1 2 2 Lay the two end pieces with the pre assembled chain on the ground with the chain lying as straight as possible be tween...

Страница 16: ...ver the connector 5 Place the two fixing brackets 2 over the rail 4 and screw these firmly onto the door operator housing with the enclosed self tapping hexagon screws 6 x 15 mm 1 2 3 4 5 Key 1 Self t...

Страница 17: ...further inward The full rail length can then be used as a result NOTE When fitted to the ceiling the distance to the door leaf must be a maximum of 25 cm Otherwise perforated brackets must be used se...

Страница 18: ...6 x 80 mm to the header bracket 1 B Installation of the fixing bracket 5 at the door operator head 7 1 Push the fixing bracket 5 onto the rail 4 as close to the door operator head 7 as possible Mark...

Страница 19: ...ey 8 Door bracket 9 Bolt 8 x 20 mm 10 Self tapping hexagon screw 6 x 15 mm 11 Securing bolt 2 x 20 mm 12 Door connector bent 8 10 11 9 12 Place the door bracket 8 on the top edge of the garage door an...

Страница 20: ...slipping out 3 4 C Installation of the door bracket 8 5 9 1 13 14 Fit the middle support 13 clip at a suitable place as near as possible to the middle point between the door and the door operator hea...

Страница 21: ...e light goes on and the unit gives a single beep and the display shows 0 at regular intervals 1 Establish operational readiness of the door Important notes after installation u Afterinstallation ensur...

Страница 22: ...setting order specified 1 Press P for approx 5 seconds Setting limits setting the upper limit 2 The door operator beeps and shows 1 3 Press P 1 flashes 5 The door opens or closes 6 If the door has mo...

Страница 23: ...ve fulfilled the basic settings required for safe operation If you do not require any further settings you must conclude programming as specified in method 1 on page 27 in order to adopt the basic set...

Страница 24: ...Press or press to select the stage After a resetting of the power level it is absolutely necessary to repeat the reference run for power limiting and to conclude the programming again u During the ref...

Страница 25: ...ng NOTE Before the door closes automati cally the door operator beeps for 20 seconds At the same time the light flashes When the door starts closing the light shines durably and it beeps permanently A...

Страница 26: ...nt of lubricant to all moving parts regularly 2 Press press several times if necessary until 7 is displayed 2000 cycle alarm setting 3 Press P the display is 0 0 off factory setting 4 Press the displa...

Страница 27: ...rogramming 2 Keep P pressed for 5 seconds 3 0 will be displayed at regular intervals in order to conclude the programming and set the door operator into an idle state Method 1 Carry out this method wi...

Страница 28: ...hand transmitter After that you can also register further hand transmitters You can register a maximum of 16 additional transmitters 1 Press S and keep pressed 2 As acknowledgement a green point will...

Страница 29: ...ctronics If the external buttons are not connected properly the operational safety of the equipment is at risk Always mount the internal button programming button etc outside the reach of movable part...

Страница 30: ...tor After that you can move the door freely Manual door operation 1 If power recovers Operate the hand transmitter or the wall switch 1 NOTE Engagement happens automatically There is a risk of injury...

Страница 31: ...oor operator has been disengaged refer to page 30 i Notes for use Check the operator system to determine whether it moves smoothly the first time the garage door operator is used After some time in us...

Страница 32: ...er doors 76 65 kg for one piece doors 220 240 10 20 40 Guide rail and available sizes Item no max total lenght Height of travel max lifting height 4201 70 61 3140 mm 2310 mm 2250 mm 4202 70 61 3740 mm...

Страница 33: ...elease may have been triggered There is not sufficient lubricant be tween the rail and the chain slide after long use The chain is loose due to long use without lubricant between the rail and the chai...

Страница 34: ...ry directive and 2014 53 EU Radio Equipment Directive The full text of the EU declaration of conformity is included with the product and is kept on file by the manufacturer RADEMACHER Ger te Elektroni...

Страница 35: ...i 35 EN...

Страница 36: ...Subject to technical changes printing errors and mistakes Illustrations not binding RADEMACHER Ger te Elektronik GmbH Buschkamp 7 46414 Rhede Germany...

Отзывы: