18
8.1 Alarm Triggered
When an alarm condition is exceeded, the alarm icon will flash
(visual) and the
alarm beeper will sound (audible). To silence the beeper, press any key.
8.2 Check the Max and Min Alarms Value
To view the current alarm settings, press the
ALARM
key to enter the alarm mode.
HI AL 1 will be displayed in the date area. At the same time Alarm 1 time and HI
alarm parameters of indoor temperature and humidity, outdoor temperature and
humidity, 1h rainfall, absolute pressure, wind gust, wind average are displayed.
Press
ALARM
key again to view the LOW alarms along with the alarm clock time the
same way HI alarms.
Press ALARM key again to return to normal mode.
Press the
SNOOZE/LIGHT
key at any time to return to the normal mode in alarm
mode.
8.3 Setting the Alarms
Press
ALARM
key to enter the alarm mode.
Press and hold the
SET
key for three seconds. The first alarm parameter will begin
flashing (alarm hour).
To save the alarm setting and proceed to the next alarm parameter, Press (do not
hold) the
SET
key.
To adjust the alarm parameter, press the
C
or
MAX/MIN/-
key to
increase or decrease the alarm settings, or press and hold the
C
or
MAX/MIN/-
key for three seconds to increase or decrease the alarm settings rapidly.
Press the
ALARM
key to turn on (the alarm icon will appear ) and off the alarm.
Press the
SNOOZE/LIGHT
key once at any time to return to the normal mode. After
30 seconds of inactivity, the alarm mode will time out and return to normal mode.
The following is a list of the individual alarm parameters that are set (in order):
1.Alarm hour(alarm 1)
2.Alarm minute(alarm 1)
3.Alarm hour(alarm 2)
4.Alarm minute(alarm 2)
5.Wind Gust HI alarm
6.Wind average HI alarm
7.Outdoor temp HI alarm
8.Outdoor temp low alarm
9.Outdoor humidity HI alarm
10.Outdoor humidity low alarm
11.Outdoor feels like HI alarm
12.Outdoor feels like low alarm
13.Outdoor dew point HI alarm
14.Outdoor dew point low alarm
15.Rainfall (1h) HI alarm
16.Rainfall (24h) HI alarm
17.Absolute pressure HI alarm
18.Absolute pressure low alarm
19.
Relative pressure HI alarm
20.Relative pressure low alarm
21.Indoor temperature HI alarm
22.Indoor temperature low alarm
23.Indoor humidity HI alarm
24.Indoor humidity low alarm
Содержание WF-100C Lite
Страница 32: ...31 3 When the registration is completed successfully will pop up the page below ...
Страница 89: ...88 In Ihrem Posteingang sollten Sie nun eine entsprechende E Mail vorfinden ...
Страница 95: ...94 Klicken Sie nun abschließend auf die mit Create bezeichnete Schaltfläche ...
Страница 110: ...109 ...