5
3.
Unscrew pivot screw (613 71) and remove lever
(159 60). The tube and shuttle assembly (925
82) can be removed by unscrewing locking ring
(170 60) to face of locking bush (171 60) and
then screwing locking bush into body until tube
and shuttle can be withdrawn.
Cleaning/Replacement of Parts
4.
Parts can be cleaned using a proprietary scale
solvent. Do not use abrasives or acid solutions.
Check joints and replace if necessary.
5.
When ordering spares, please state type of
mixing valve for which they are required, the
part names and their numbers.
Parts List
002 61
Cover
005 60
Body
045 87
Nameplate
050 60
Spring
089 60
Drain plug
156 60
Splined bush
159 60
Lever
165 60
Gland ring
170 60
Locking ring
171 60
Locking bush
190 08
Body
193 08
Clack
195 08
Facing - water
195 11
Facing - steam
196 08
Cap
556 47
Pin - locating
602 08
Screw-cover (12)
610 91
Screw
613 69
Screw - cover Stop 121
613 71
Screw - pivot
620 42
Acorn nut
623 22
Gland nut
634 52
Cover joint
634 33
Cap gasket
639 66
Washer
641 15
Gland packing
901 60
Thermostat assembly
909 08
Clack assembly - water
909 11
Clack assembly - steam
916 60
Temperature regulating handle assembly
925 62
Tube and shuttle assembly
Re-Assembling
6.
Place shuttle on tube and insert these parts
into body, ensuring that small cut-out at end of
tube is firmly located by locating pin (556 47).
7.
Locate other end of tube into locking bush and
unscrew locking bush from body until tube is
rigidly held in position..
8.
Tighten locking ring hard against body. If drift is
used for this purpose, do not damage locking
ring.
9.
Re-assemble lever, so shuttle driving pin is
located in centre hole, then replace pivot screw
and tighten firmly.
10.
Re-fit thermostat assembly into cover. Replace
gland packing, gland ring, spring and gland nut.
Check cover joint is in position.
11.
Replace cover ensuring thermostat driving pin
locates into vacant slot of lever at opposite end
to pivot screw. Refit cover screws.
12.
Re-set maximum temperature, as earlier
described.
Check Valves
Check valves will not operate satisfactorily if
deposits form on seats or if seats become damaged.
Hot water or steam entering cold supply or vice versa
indicates service is necessary.
To service check valves, first isolate supplies.
Remove cap (196 08). Clean seat using a proprietary
scale solvent. Slight damage to seats can usually be
lapped out, otherwise check valve must be replaced.
Examine clack facing (195 08 or 195 11) and if
damaged replace. When replacing clack facings
ensure facing screw (610 91) is firmly tightened.
Check cap gasket (634 33) is in good condition.
Should you experience a problem not covered by
these instructions, our advice should be sought.
Содержание ts202
Страница 1: ...SHOWER FITTINGS Deutsch English Fran ais Italiano Japanese Nederlands Ts202 rada...
Страница 10: ...10...