background image

VI

Operation Instruction

Temperature

 

Sensor

L

imiting Temperature Range

Temperature Control Accuracy

Working

 

Voltage

Current Load

 

Setting Temperature Range

NTC

 

 ±

1ºC

1

.

5

Vx2

(

Two sections of 1.5V 5 battery

)

3A

Consumption

5-60

I. Product Summary:

II. Technical Parameter:

IV. User Interface Explanation

 

BOT SERIES BOILER THERMOSTAT

III. Main Button Instruction

V. Model Spec

BOT-W306

BOT-X306

BOT series

 

boiler

 

thermostats

 

are

 

with

 

LCD

 

digital

 

display

 

big

 

screen

and

 

it

 

is

 

developed

 

according

 

to

 

market’s

 

requirements. Thermostats can

be installed on the wall, or directly put on the table. This

 

series

 

thermostats

 

are

 

easy

 

to

 

operate

and

 

with

 

complete

 

functions. It

 

can

 

be

 

used

 

to

 

control

 

boilers

motorized

 

ball

 

valves

motorized

 

valves

electric

 

valves

solenoid

 

valves

etc

.

Output

 

power can be made 220V/110V

5-99ºC

<0.3W

: ON/OFF Switch;

:Mode Button. Switch between       Manual Mode,         Auto Period 
Control Mode,        Temporary Manual Mode. Long press to enter 
period setting.

:Time Set. Hour, minute and week setting;
:Up Button. To increase temperature. When press it with       and 
it can set programmable function;

 

:Down Button. To reduce temperature. When press it with       and 
it can set programmable function;

 

: Key Lock. Long press       5 seconds to lock or unlock;

 

Model

Wi-Fi Function

Wireless Function

Terminal Receiver

:Manual Control.          :Temporary Manual Control.     :Auto Control.

:Heating.

:First Period. Wake up in the morning.

:Second Period. Out of home in the morning.

:Third Period. Go home in the afternoon.

:Forth Period. Out of home in the afternoon.

:Fifth Period. Go home in the evenning. 

Open/Close

State

Power

Power Indicator Light

State Indicator Light

Switch Indicator Light

:Sixth Period. Sleep in the evening.

Time Setting

Press      , the time area will display Minute, Hour and Week, then press
      or      to modify time.

Programmable Period Temperature Setting

6 periods every day 
in a week

5+2 Controls 1 2 3 4 5

6+1 Controls 1 2 3 4 5 6

7+0 Controls 1 2 3 4 5 6 7

A Week Loop Control

3. Press one time, time twinkles, 
you can set the time during this period

.

 

time during this period.

1. After Power is on, long press 5 seconds 
to enter period program. Loops means a
 Week loop.

2. Press again, room temperature display 
and twinkle, you can set the temperature 
during this period.

4. Press again, to set the next period 
temperature and time with the same method.

First step

, long press      , screen display 

LooP

(Cycling Control), screen

displays 

12345

 (From Monday to Friday); Press       one time, it displays

123456

(From Monday to Saturday); Press         two times, it displays 

1234567

(From Monday to Sunday); 

Second step

, time and temperature setting in every period. When screen

display 

12345

 or 

123456

 or 

1234567

, press     to enter temperature setting.

Press      to enter time setting. To modify and save through       or       .

Att: When auto-control      ,if user needs to reset the temperature, it can 
be changed to temporary manual control. Temporary manual control means
when thermostat is in auto-control mode(program mode), user press
or      to modify temperature setting, thermostat now is in temporary manul
control state. When next periods comes, thermostat will automatically
return to acquiescent period program control mode.   

Programmable Period Time Setting 

First press      , then press      to change to time options, user can modify 
time in the period.

Default Program Data

Period

Default Time

Default Temperature

Icon

1
2

3
4
5
6

Workday

Weekends

1
2

06:00

08:00
11:30
12:30
17:30
22:00
08:00

23:00

20

15

15

22

22

15

15

15

Att

:

1

.

The default temperature values of 3 and 4 period

in workday is same with 2 period. If user need, 
please change this default temperature.

2. Setting temperature is 

00,

 it means this period 

is power off.

 

Set, or modify parameter

: Anti-frozed function open.

BOT306RF-WIFI

VII. Advanced Setting

In the state of power-off, long press and hold       then press     into advanced 
setting mode. Then press     to set relative item.  

   

  Firstly, press time button

Then, press power button

After entering advanced setting, press     to 
choose next parameter changing.

Отзывы: