background image

Display Code

Function

Setting And Options

Factory Default

dIF

Limit temp. return
difference

0.5-4.5

2

SVH

Set temp. upper 
Limit 

5-99

35

SVL

5-99

5

AdJ

Measure temp.

-5-5

(0.5

accuracy

correction)

0

.

0

FrE

Anti-frozen

00

Close anti-frozen

01

Open anti-frozen

00

LOC

Button lock 
function

00: Unlock
01: except power switch,
     all buttons are locked
02: All buttons are locked

00

SNP

Set Sequence 
Number

0

FAC

Factory setting

08

Just display

00

Return to factory setting

08

Set temp. low 
limit

00

Close this function

01

Open this function

VIII. Wiring Diagram

NC

:

Normally

 

Closed

 

Interface

 

    (

Boiler

 

or

 

Loading

)

;

COM

:

Common

 

Interface

 

     (

Boiler

 

or

 

external

 

power

 

input

)

;

NO

:

Normally Open

 

Interface

 

   (

Boiler

 

or

 

Loading

)

;

Att:

 Installation wires should be changed to be 1

.

5

-

2

.

5mm² hard line. 

Please rightly connect the wires strictly according to the connect diagram.
Don’t make water, mud and other debris into the thermostat, otherwise
it will damage the thermostat.

The button inside receiver is Reset button. When status indicator light stay on 
or not on, user can press reset button to resume normal work.

IX. WIFI Configure

1. Install APP on phone

For iOS system: Login in App Store, search “ 

Beok  RF Boiler

”, you can 

download it on your iphone.

For Android System: Login in Google Play, search “

”, you

 can download it on your phone.  

Beok RFBoiler

2. Connection Thermostat with Phone

Thermostat Setting

Turn-off

 

Press UP button for 10 seconds

1. Download and  Install APP on phone.
2. Press thermostat       button for 10 seconds when thermostat is in 
turn-off state, then WIFI signal will appear and quickly twinkle. 
3. Enter your wifi name and password, then start connection configure. 

Press Configure key

Press Search key

APP Interface on the Phone

Thermostat Name

Return

Refresh

Room Temperature

Heating State

Screen Locking

Anti-freezing

Long press into Advanced Setting

Manual/Auto mode

Power Switch

Period Display

Time Matching

Set Temperature
Adjustment(down)

Current Temperature

Set Temperature

Thermostat Setting through Phone Operation

1. Clock : You can press Time Matching         switch to match your phone 
clock with thermostat clock.

2. Children lock (screen locking) : Press          to lock the thermostat.

3. Anti-Freezing: Press        thermostat will show         on the screen , it 
means Anti-freezing function open.

4. Temperature setting: You can 

drag the pointer           on 

Temperature Setting Dial to set temperature. Or press      and

   

 to set 

temperature step.

directly 

>

 

5.Period setting: Long press Period Display,                                        then 
you will go into the Period Setting mode:

v

v

Отзывы: