OPERATING INSTRUCTIONS

OAKTON WD-35627-00, -02

TEMP TC

Acorn Series Meters

R1 Printed in the U.S.A. 9/00

TEMP JKT
Acorn series

Thermocouple

Thermometer

ON

OFF

CAL

HOLD
ENTER

°

C/

°

F

J-K-T

MAX

MIN

9. Warranty

OAKTON warrants this meter to be free from significant deviations in material and
workmanship for a period of one year from date of purchase. OAKTON warrants
this probe to be free from significant deviations in material and workmanship for a
period of six months from date of purchase. If repair or adjustment is necessary and 
has not been the result of abuse or misuse within the warrantied time period, please
return—freight prepaid—and correction will be made without charge. OAKTON
alone will determine if the product problem is due to deviations or customer misuse.

Out-of-warranty products will be repaired on a charge basis.

10. Return of items

Authorization must be obtained from your OAKTON distributor before returning
items for any reason. When applying for authorization, please include data regard-
ing the reason the items are to be returned. For your protection, items must be care-
fully packed to prevent damage in shipment and insured against possible damage or
loss. We will not be responsible for damage resulting from careless or insufficient
packing. A restocking charge will be made on all unauthorized returns.

NOTE

: We reserve the right to make improvements in design, construction, and

appearance of products without notice.

Содержание TEMP TC

Страница 1: ...please return freight prepaid and correction will be made without charge OAKTON alone will determine if the product problem is due to deviations or customer misuse Out of warranty products will be repaired on a charge basis 10 Return of items Authorization must be obtained from your OAKTON distributor before returning items for any reason When applying for authorization please include data regard ...

Страница 2: ...ensor 6 3 3 Switching the meter on 7 4 Measurement 8 9 4 1 Measuring temperature 8 4 2 Displaying minimum and maximum temperature 8 4 3 HOLD function 9 4 4 Minimum and maximum hold mode 9 5 Calibration 10 5 1 Temperature calibration using offset adjustment 10 6 Troubleshooting 11 7 Specifications 12 8 Accessories 13 9 Warranty 16 10 Return of items 16 ...

Страница 3: ...e basic instructions that will get you up and running quickly The remaining sections of this manual 6 through 11 deal with error messages and troubleshooting This part of the manual also includes the Specifications Accessories Warranty and Return of Items section 2 Display and Keypad Functions The Acorn Temp TC meter has a large custom LCD with the following indicators C HO J K T LO F MAX MIN Degr...

Страница 4: ...perature sensor Insert the mini connector plug of the temperature sensor into the connector on the side of the meter Note the negative pin is larger than the positive pin be sure to properly align the pins Unplug the sensor when not in use 7 6 3 1 A A temperature probe connections on side of Acorn TC meter 3 2 Switching the meter on Press the ON OFF key to power up your meter All the LCD segments ...

Страница 5: ... HOLD function is activated See figure Press HOLD key again to deactivate the HOLD function and return to measurement mode Minimum and Maximum Hold Mode With Minimum and Maximum Hold Mode the Acorn TEMP TC meter can be used as a maximum registering or minimum registering thermometer The meter will display the lowest or highest temperature measured since entering the Maximum or Minimum Hold mode 1 ...

Страница 6: ...e maximum adjustment is 10 C 18 F from factory default 5 Press ENTER key to confirm calibration The LCD displays CO and the meter then reverts to measurement mode 5 1 A B C A B 6 Troubleshooting Problem Cause Solution Ur or Or Measurement over Or or on LCD Under Ur range Bad temperature Change temperature probe probe oPEn annunciator Probe not connected Make sure probe on LCD is firmly connected L...

Страница 7: ...e K Type T Range 200 to 1000 C 250 to 1372 C 250 to 400 C 328 to 1832 F 418 to 2502 F 418 to 752 F Resolution 0 1 C from 99 9 C to 299 9 C 0 1 F from 99 9 F to 299 9 F 1 C F outside this range Accuracy 0 25 of reading plus 1 C 2 F for temperatures 99 9 C F 0 2 of reading plus 0 5 C 0 9 F for temperatures 99 9 C F Calibration factory calibrated push button offset adjustment Input connector standard...

Страница 8: ...15 14 ...

Отзывы: