       Digital Output 
Configuration Screen: 

 

 
 
 

Display Functions: 

 

 

Absolute Position  

 

On / Off selection of Outputs 

 

Limit Positions 

 
 
 
 

Input Functions:

 

 
 

Setting of End of Stroke Limits 

 

Setting of Intermediate Limits 

 

Selection of Output function 
On/Off or Off/On 

 

Enable PWM (only EPS06) 

 

Width of Hysteresis 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Digital  output  configuration:

  The  screen 

provides  an  easy  selection  of  assigning 
stroke  limit  switching  points  over  the  entire 
stroke length of the actuator. Each of the two 
output  channels  have  a  selection  of  up  to 
nine  independent  switching  points  for  up  to 
eight  independent  stroke  setpoints.  The 
selection  of  each  switching  point  can  be 
active high or active low. If not all switching 
points  are  used  a  negative  one  in  the  field 
switch  position  will  turn  off  the  associate 
fields. 

Hysteresis:

  The  selected  hysteresis  number 

provides a negative and positive band around 
the  selected  switching  point.  This  number 
should  be  selected  large  enough  to  avoid 
shattering  of  the  output  signal  and  small 
enough  to  provide  the  desired  position 
accuracy. 

Function  of  Output  4  (EPS06  only):

 

Output channel four can be switched from a 
position limit output signal to a Pulse Width 
Modulation (PWM) output signal. The signal 
parameters  are  selected  in  the  following 
“Analog  Output  Configuration”  screen 
description.  The  PWM  signal  has  a  carrier 
frequency  of  1kHz  and  the  “on”  and  “off” 
time  of  the  square  pulse  signal  is 
proportional  to  the  selected  stroke  length. 
The signal output is immune to noise and an 
inexpensive alternative to analog input  

 

channels  on  customers  PLC  control 
equipment. 

Impulses  per  Revolution  of  Square 
Wave  Signal  at  Output  5+6  (EPS06 
only):  

The  frequency  of  the  90°  phase  shifted 
A B encoder signal can be selected from 
32, 64, 128, 256 pulses per revolution of 
the  sensor  head.  This  gives  the  user  a 
wide range to adapt the encoder to VFD 
or PLC input cards.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание EPS 02

Страница 1: ...an be used Three on board LED s will guide the user through the initial setup procedure and will function thereafter as operation control signals Function The EPS 02 consists of two potential free rel...

Страница 2: ...e hard wired into the reversing motor starter or VFD control circuit to provide reliable end of stroke protection Within the permissible stroke range of the actuator the contacts are closed Relay outp...

Страница 3: ...om one function to the next Push button S2 is used to select the value in each of the selected function There are two settings which can be made independent from each other 1 Setting of the end of str...

Страница 4: ...LED pattern will change to its normal operational condition See above LED Display section Manual Position Setting Diagram TTL Level Communication Interface The EPS02 is equipped with a TTL level comm...

Страница 5: ...n to the stroke direction A counting direction will be selected with the radio buttons External Reference Function If an external reference switch is used this selector box will be enabled The positiv...

Страница 6: ...the screen into the EPS02 the Send Parameter Block button needs to be pushed This refers to all configuration screens Reed switch sector The reed switch sector display block is for diagnostic and func...

Страница 7: ...a negative and positive band around the selected switching point This number should be selected large enough to avoid shattering of the output signal and small enough to provide the desired position...

Страница 8: ...ollowing selections can be made 0 10V 10 0V 0 20mA 20 0mA 4 20mA and 20 4mA Based on the selection Cylinder max Stroke from the main screen the Limits for Analog Output Signal slide bar is initialized...

Страница 9: ...of the EPS06 As soon as the forward or reverse auxiliary contacts of the reversing motor contactor or VFD circuit are pulled in the on delay timer with the predefined Motor Rush in Time Delay Retract...

Страница 10: ...he main cylinder setting screen changes from red to green Connection Problem Trouble Shooting The most common problem is the incorrect selection of the COM Port With the EPS02 EPS06 connected and powe...

Страница 11: ...m Examples The EPS 02 limit switch contacts are hard wired into the reversing motor starter circuit The EPS 02 output signals are wired as permissive signals into the control circuit of a variable fre...

Отзывы: