Alert at Trigger
Select to enable audible and visual alert signals when the decel test's trigger test has started. The unit will briefly beep
and the 4 LEDs across the top of the device will flash
green
.
Alert at End
Select to enable audible and visual alert signals when the decel test's end speed criteria are met. The unit will beep and
the 4 LEDs across the top of the device will flash
green
.
Write Results File
Select this option to enable the decel test results to be written to an inserted SD card.
If the unit cannot detect an SD card, this option will be greyed out.
If you press it when it is greyed out:
• the unit will beep
• the 4 LEDs across the top of the device will flash
red
• the unit will emit an audible tone
• a 'NO SD CARD' message will display
MFDD Settings
This area allows you to set up the start and end periods of the Mean Fully Developed Deceleration (MFDD) analysis
period.
https://en.racelogic.support//Product_Info/Displays/MFD_Touch/MFD_Touch_User_Guide/05_-_MFD_Touch_Settings