Table 4-1, Default Limit Settings After Power On, *RST
Power Supply Voltage Limits:
Power Supply (PS)
Maximum
Minimum
+5V
5.25V
4.87V
-5.2V
5.04V
5.46V
-2V
-1.90V
2.10V
+24V
25.20V
23.28V
-24V
-23.28V -25.20V
+12V
12.60V
11.64V
-12V
-11.64V -12.60V
Power Supply Current Limit:
Power Supply (PS)
Maximum
+5V
80A
-5.2V
60A
-2V
30A
+24V
12A
-24V
12A
+12V
17A
-12V
17A
Fan Speed Limit:
2000
RPM
Minimum
4999
RPM
Maximum
Absolute Temperature Limit
55
o
C
Ambient
Temperature
Limit
: 55
o
C
Slot Temperature Rise Limit:
30.0
o
C
Number of VXI Bus Errors/IACKs:
0 (disabled)
Power On Time Limit:
1
year
Cumulative Power-On Time Limit:
5 years
Filter Service Time Limit:
4320 hours of power-on time (180 days)
Trigger In/Trigger Out Delay:
0.0
Seconds
TRIG IN Input:
Disconnected
TRIG OUT Output:
Disconnected
Front Panel Display State:
On
Front Panel User Message:
None
RS-232 Baud Rate:
9600 (set by DIP switch SW1)
RS-232 Parity:
None (set by DIP switch SW1)
RS-232 Data Bits:
8 (set by DIP switch SW1)
RS-232 Stop Bits:
1 (set by DIP switch SW1)
Current Sharing Option 53:
Disabled (set by DIP switch SW1-7)