background image

INSTRUCTIONS

EZPAN® HE INSTALLATION

RAB Lighting is committed to creating high-quality, aff ordable, well-designed and energy-effi  cient LED lighting and controls that make it easy for electricians to install

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]

0-10V DIMMABLE WIRING

Universal voltage driver permits operation at 120V thru 277V, 50 or 

60 Hz. For 0-10V Dimming, follow the wiring directions as shown 

(Fig. 5)

1.  Connect the black fi xture lead to the

 LINE

 supply lead.

2.  Connect the white fi xture lead to the 

COMMON

 supply lead.

3.  Connect the 

GROUND 

wire from fi xture to supply

 GROUND

4.  Connect the purple fi xture lead to the (V+) DIM lead.
5.  Connect the pink 

(or gray) 

fi xture lead to the (V-) DIM lead.

NOTE:

Do not connect DIM V+ (purple)/ DIM V- (pink/gray) to line 

voltage 

Fig: 5

PINK (or GRAY)

LIGHT

FIXTURE

Vaux 12V

YELLOW

GROUND

GROUND

( - ) DIM V

( + ) DIM V

COMMON

LINE

BLACK

WHITE

PURPLE

CLEANING & MAINTENANCE

CAUTION: Be sure fi xture temperature is cool enough to 

touch. Do not clean or maintain while fi xture is energized.

TROUBLESHOOTING

1.  Check that the line voltage at the fi xture is correct.  

Refer to wiring directions.

2.  Be sure the fi xture is grounded properly.

1.  Clean polycarbonate lens with non-abrasive cleaning solution.
2.  Do not open the fi xture to clean the LEDs. Do not touch the LEDs.

SAFETY INSTRUCTIONS

WARNING: 

Risk of fi re or electric shock. Suitable for damp locations. 

WARNING: 

Suitable for 9/16” or 15/16” Flat Tee Grid in both

 

insulated ceilings and non-insulated ceilings. 

 

Access above ceiling required. 

WARNING: 

Do not handle energized fi xture when hands are wet, 

 

when standing on wet or damp surfaces, or in water.

WARNING: 

Vapor barrier must be suitable for 90°C.

WARNING: 

Fixture to be independently supported to 

 

building structure.

Note: These instructions do not cover all details or variations in equipment nor 
do they provide for every possible situation during installation, operation or 
maintenance.