INSTRUCTIONS
FIELD-ADJUSTABLE SR™ INSTALLATION
RAB Lighting is committed to creating high-quality, aff ordable, well-designed and energy-effi cient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
V-HOOK / CHAIN MOUNTING
The fi xture can be mounted using
V-Hooks
and
Chain
(ordered
separately, CAT# SR VHOOK KIT)
.
1. Loop the
V-Hooks
into the
Mounting Slots
to each end of the
Fixture Housing
as shown in Fig. 4.
2.
Connect the
Chains
to the mounting surface and hang the
Fixture
from
V-Hooks
as shown in
Fig. 5.
3. Fixture mounting height and spacing should be determined
by application requirements.
V-Hook
and
Chain i
s suitable to
support four
(4)
times the weight of the Fixture.
4. Press and hold the
Release Buttons
(4)
on both sides of the
Fixture Housing
to release the
Lens
(Fig. 1)
. When pressing the
Release Buttons
use one hand to hold the
Lens
and press the
Release Buttons
on both sides of the
Fixture
with the other hand.
CAUTION: The Lens may drop out quickly
. Lens
is supported
with
(2)
Tether Cables
(Fig. 3).
5.
Make electrical connections as shown in wiring diagram
(Fig. 12)
. Use approved wiring connectors and suitable conduit
(not provided)
. Wire to local NEC codes. Push all wires back into
Fixture Housing
. Be careful not to pinch wires.
6.
Snap
Lens
back into
Fixture Housing
and remove protective
plastic from
Lens
.
WARNING: To prevent wiring damage or abrasion, do not expose
wiring to sharp objects.
Mounting Slots
Fig: 4
V-Hook
Chain
V-Hook
Chain
Mounting Surface
Fig: 5