background image

http://echoring.com

Revision: 1

generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, wich can
be determined by turning the equipment off and on, the user encouraged to try to correct
the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to wich the receiver

is connected.

• Consult the dealer or an experienced radio/TV technician for help.

!

ATTENTION

— This equipment complies with FCC radiation exposure limits set forth for an uncontrolled

enviroment. Under normal use condition the user has to keep at least 20cm separation distance between
radiator and body of the user.

!

ATTENTION

— This transmitter must not be co-located or operating in conjunction with any other antenna

or transmitter.

!

ATTENTION

— Professional Installation Notice: To comply with FCC Part 15 rules in the United States,

the system must be professionally installed to ensure compliance with the Part 15 certification. It is the
responsibility of the operator and professional installer to ensure that only certified systems are deployed in
the United States. The use of the system in any other combination (such as co-located antennas transmitting
the same information) is expressly forbidden.

3.4.2 RSS-210 of ISED

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation,

Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject
to the following two conditions:

1. this device may not cause interference, and

2. this device must accept any interference, including interference that may cause unde-

sired operation of the device.

L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme
aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux ap-
pareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:

1. L’appareil ne doit pas produire de brouillage;

2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est

susceptible d’en compromettre le fonctionnement.

This device has been designed to operate with dipole antennas having a maximum gain

of 8.5 dBi. Antennas having a gain greater than 8.5 dBi are strictly prohibited for use

with this device. The required antenna impedance is 50 ohms. To reduce potential radio

interference to other users, the antenna type and its gain should be so chosen that the
equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for suc-
cessful communication. That the device for the band 5,150-5,250 MHz is only operated
indoors to reduce potential for harmful interference to co-channel mobile satellite systems.

3. Product Information

Page 4 of 11

© by R3 – Reliable Real-time Radio

Содержание EchoRing ER-EB 1000M

Страница 1: ...ING ETHERNET BRIDGE User Manual ER EB 1000M Version for USA and Canada Contact Information R3 Reliable Realtime Radio Communications GmbH Bismarckstraße 10 12 www echoring com 10625 Berlin contact r3coms com ...

Страница 2: ...http echoring com Revision 1 by R3 Reliable Real time Radio ...

Страница 3: ...Product 3 3 4 Conformity Country Approvals 3 3 4 1 FCC 47 CFR 15 Compliance 3 3 4 2 RSS 210 of ISED 4 4 Installation 5 4 1 General 5 4 2 Mechanical Installation 5 4 2 1 DIN Rail Mounting 5 4 2 2 Wall or Mast Mounting 6 4 3 Connectors 6 4 4 LED Indicators 7 5 Web based Configuration Interface 8 5 1 General Information 8 5 2 Set Up and Access Web User Interface 8 5 3 Configure the Device 8 5 4 Repla...

Страница 4: ...http echoring com Revision 1 by R3 Reliable Real time Radio ...

Страница 5: ...r time The user must ensure the product is used correctly according to this document s guidelines in particular observing all relevant standards and regulations This document including all diagrams and illustrations is copyright protected Any and all changes violate our Terms of Use ATTENTION Installation must only be performed by qualified specialist personnel by R3 Reliable Real time Radio Page ...

Страница 6: ...d instructions throughout the docu ment TIP Text in this format is information explaining the use of the product ATTENTION Text in this format must be observed in order to avoid malfunction and or damage or to avoid potential security risks 2 Please Observe the Following Notes Page 2 of 11 by R3 Reliable Real time Radio ...

Страница 7: ...tance 3 2 Localization Information and Constraints The EchoRing Ethernet Bridge ER EB 1000M Version for USA and Canada was specifically designed to meet regulatory requirements of the FCC and ISED respectively The Device operates in the 5GHz Band more specifically Channels 36 40 44 48 149 153 157 161 and 165 The maximum output power at the SMA port is limited to 16 2dBm For any installation use di...

Страница 8: ...ed in the United States The use of the system in any other combination such as co located antennas transmitting the same information is expressly forbidden 3 4 2 RSS 210 of ISED This device contains licence exempt transmitter s receiver s that comply with Innovation Science and Economic Development Canada s licence exempt RSS s Operation is subject to the following two conditions 1 this device may...

Страница 9: ...cs of the wireless channel when deploying devices Placement of devices may need to be adjusted during functional testing 4 2 Mechanical Installation Figure 4 I Dimensions are in millimeters mm Screw the antenna to the device s SMA connector Note antenna is excluded from diagram 4 2 1 DIN Rail Mounting Figure 4 II DIN rail mounting 1 Use the self tapping screws provided to attach the device to DIN ...

Страница 10: ...Attaching wall mounts to a device is irreversible 4 3 Connectors Figure 4 IV Connectors TIP The Ethernet connector is PoE Power over Ethernet and can also be used to supply power to the device Figure Pins Function 1 Power supply 9 30 V DC 2 Ground for digital input 3 Ground for power supply 4 Digital input 9 30 V DC 5 Functional ground Table 4 i Power connector M12 plug A coded ATTENTION The signa...

Страница 11: ...Green flashing Traffic data is being sent through the device CFG Off Device is in operational mode Green Device is in configuration mode Green flashing Device is updating its firmware HLT Green Device is running successfully according to configuration Red Device does not run Device is either out of range of other devices or a software related problem has occurred ETH CFG Green flashing Device is i...

Страница 12: ...the PC s network settings and configure the static IP address 10 10 100 99 and the subnet mask 255 255 0 0 4 Open a web browser and enter the URL http 10 10 100 100 ATTENTION The web based user interface is designed for the web browsers Firefox version 60 or newer and Chrome 64 or newer Other browsers may not support full functionality 5 3 Configure the Device 1 Set up and access the Web User Inte...

Страница 13: ...ach i 6 Apply prioritized traffic filter if needed in bottom field under Priority Traffic by entering the prioritized data s byte index counted from the start of the MAC header and its Byte value EXAMPLE Profinet EtherType MAC header 0x88 0x92 Byte Values Byte index 12 13 i To filter for additional other packet aspects such as IP addresses packet flags QoS fields or similar add additional entries ...

Страница 14: ...for the EchoRing protocol TIP In order to make sure network is configured to allow application traffic s cycle time packet length and data rate it is recommended to start with minimum reliability first and then go back and increase reliability after all parameters been set Value Function 1 minimum Minimal reliability measures allowing higher performance in terms of throughput and lower latency 8 m...

Страница 15: ... has a cycle time of 16 ms packets received later may cause application stop the system should ideally be configured with a Targeted Token Rotation Time shortly below 8 ms to allow timing jitter i TIP If the application s data rate exceeds the maximum throughput set by the latency packet length reliability parameters or each device s configured capacity the system becomes overloaded and the packet...