3.4 Connectors
Figure 3I: Connectors
TIP
— The Ethernet connector is PoE (Power over Ethernet) and can also be used to supply power to the
device (48 VDC, PoE 802.3at Type 1).
Figure
Pins
Function
1
Power supply 24 VDC (+/ 10%)
2
Ground for digital input
3
Ground for power supply
4
Digital input + (9 – 30 VDC)
5
Functional ground
Table 3i: Power connector (M12 plug, A coded)
Figure
Pins
Function
Color Mark (T568B)
1
Send
Orange/white
2
Receive
Green/white
3
Send
Orange
4
Receive
Green
Table 3ii: PoE/Ethernet connector (M12 plug)
3.5 LED Indicators
LED
Color/pattern
Meaning
Power
•
Off
No power.
•
Green
Device is connected to power.
Ethernet
•
Green
Ethernet physical layer was able to establish
a connection to another device.
Config
•
Off
Device is in Deployment Mode.
•
Green
Device is in Configuration Mode and a
Configuration Server was found.
•
Green blinking (slow)
Device is updating its firmware.
Page 5 of 45