5.4.1 Operation Menu (Fnc)
In this menu, you can set
power output
On/Off, toggle between “Local” or “Remote”
control mode and set the
Forward Power Good (PgD)
threshold rate.
To edit an item, highlight the appropriate line using the UP and DOWN buttons and
then press and hold the
ENTER
button until the command is accepted. This way,
Pwr setting is toggled between On and Off and Mod setting is toggled between
“x1” and “x10”. To edit the Power Good rate, simply select item “PgD” and edit its
value using buttons and
; finally, press
ENTER
to confirm.
Menu 4
Pwr
Enables (ON) or disables (OFF) amplifier power output.
Loc
Modifies machine operation. In the LOCAL mode, the machine can read
and modify its operating parameters through the navigation keys and the
management firmware, whereas all other sources are locked out. In the
REMOTE mode, the machine can only read its operating parameters;
parameters are modified based on the commands received from other
connected telemetry systems.
PgD
Modifies Power Good (forward power) threshold. The Power Good
rate is a percent of machine rated power (1000W for
PJ1000C-LCD
,
1300W for
PJ1300C-LCD
and 2000 W for
PJ2000LCD
), not of forward
output power. This means that this threshold set at 50% will give 150
W regardless of set power level. The Power Good feature enables
output power control and reporting. When output power drops below
set Power Good threshold, the machine changes the state of pin
on
the DB25 “Remote” connector located on the rear panel.