Note :
Output power can also be set in a
Pwr OFF
condition; in this condition,
(
Fwd
) output power reading on the display will be 0 (zero), whereas the
SET
bar,
which you can control using the keys, provides a graphic display of the amount of
power that will be delivered the moment you switch back to
Pwr ON
state.
5.2.6 Changing the
Power Good
alarm threshold
Change Forward Power Good alarm setting
PgD
from the
Fnc
menu as desired
(factory setting is 50%).
5.2.7 Setting equipment I
2
C address
Change the
IIC
address in the
MIX
(Miscellaneous) menu as desired (factory
setting is 01).
5.2.8 How to enable Remote mode
If you wish to use the telemetry control feature, enable Remote control in the
Fnc
menu (see section 5.3.1 for details).
Note :
In the
Remote
mode, all local push-button controls except
Remote/Local
(for switching back to Local mode) are disabled . Operating parameter readings
are available.
5.3 Operation
NOTE:
For better clarity, only the typical screens of
PJ2000LCD
are reported
below.
PJ1000/1300C-LCD
screens look the same except that full scale values
are different.
1) Power on the amplifier and ensure that the
ON
light turns on (chap. 6.1).
Machine name should appear briefly on the display, quickly followed by forward
and reflected power readings (Menu 1), provided that the amplifier is delivering
output power.
Menu 1
1b) To
modify power level setting
, hold down the
ENTER
button until opening
the
power setup menu
.
The edit screen will look like this: