background image

1

 

/ 36

User Manual

Rev. 1.0 - 28/02/11

PJ1000C/1300C/2000LCD

ELETTRONICA

  In the same menu, ensure that power limiting is disabled: if 

PWR

 is set to 

OFF

i.e. power output is disabled, move cursor to 

PWR

. Press 

ENTER 

and label 

will switch to 

ON

, i.e. power output enabled.

  Press 

ESC

 twice to go back to the 

default menu

 (menu 1).

3)  Fine tune power setting from menu 2 (see description of item 1b) until achieving 

the desired value.

 

WARNING: Machine is capable of delivering more than rated output power 

(1000/1300/2000 W); however, never exceed the specified power rating.

 

NOTE: Exciter drive power setting should never exceed 30W, or it will trigger 

an Overdrive Alarm.

 

 

NOTE: If power is set to 0 W in the 

edit mode

, the INTERLOCK OUT contact 

trips and external exciter power is immediately inhibited.

Next,  you  can  review  all  operating  parameters  of  the  machine  through  the 

management firmware.

Normally,  the  machine  can  run  unattended. Any  alarm  condition  is  handled 

automatically by the safety system or is signalled by the LED indicators on the 

panel or by display messages.

  NOTE:  Standard  factory  settings  are:  output  power  set  to  upper  limit  (unless 

otherwise specified by customer) and 

OFF

.

  5.4  Management Firmware

The machine features an LCD with two lines by 16 characters that displays a set 

of menus. Figure 5.2 below provides an overview of machine menus.

The symbols listed below appear in the left portion of the display as appropriate:

  (Cursor) - Highlights selected (i.e. accessible) menu.

  (Filled arrow) - Editable parameter marker. This symbol appears in menus that 

take up more than two lines to aid browsing.

 

(Three empty arrows) - Parameter is being edited.

  (Empty  arrow)  -  Current  line  marker;  the  parameter  in  this  line  cannot  be 

edited. This symbol appears in menus that take up more than two lines to aid 

browsing.

Содержание PJ1000C-LCD

Страница 1: ...PJ1000C LCD PJ1300C LCD PJ2000LCD USER MANUAL VOLUME1 Manufactured by R V R ELETTRONICA S p A Italy...

Страница 2: ...ed and bound in Italy No part of this manual may be reproduced memorized or transmitted in any form or by any means electronic or mechanic including photocopying recording or by any informa tion stora...

Страница 3: ...ription 9 4 6 Technical Description 11 5 Quick guide for installation and use 12 5 1 Preparation 12 5 2 First power on and setup 14 5 3 Operation 16 5 4 Management Firmware 18 6 Identification and Acc...

Страница 4: ...ii User Manual Rev 1 0 28 02 11 PJ1000C 13000C 2000LCD ELETTRONICA This page was intentionally left blank...

Страница 5: ...bility or liability for any errors or inaccuracies in this manual including the products and the software described herein R V R Elettronica reserves the right to make changes to equipment design and...

Страница 6: ...3 Figure 4 Figure 5 One rescuer give 2 quick rescue breaths after each 15 compressions Two rescuers one rescue breath after each 5 compressions Do not stop chest compressions while giving artificial...

Страница 7: ...ow the limits provided for by international standards CCIR FCC or ETSI Two major features of PJ1000C 1300C 2000LCD are compact design and user friendliness Another key feature is its modular concept d...

Страница 8: ...I2 C Four LEDs on the front panel provide the following status indications ON FAULT FOLDBACK and RF MUTE The amplifier management firmware is based on a menu system User has four navigation buttons a...

Страница 9: ...ed by an external interlock command 5 CONTRAST Display contrast adjusting trimmer on the top of the equipment 6 ESC Press button to exit from a menu 7 Press button to move in the menu system and to mo...

Страница 10: ...ellow LED lit on when the amplifier s power output is inhibited by an external interlock command 5 CONTRAST Display contrast adjusting trimmer on the top of the equipment 6 DISPLAY Liquid Crystals Dis...

Страница 11: ...upply connectors 115 230 V 50 60 Hz 5 FUSE1 Mains supply fuse 6 R F INPUT RF input connector N type 7 R F OUTPUT RF output connector 7 16 EIA flange 8 SERVICE DB9 connector for interconnection with ot...

Страница 12: ...ground 5 REMOTE DB25 connector for telemetry of the machine 6 MAINS Mains supply connectors 230 V 50 60 Hz 7 FUSE1 Mains supply fuse 8 R F OUTPUT RF output connector 7 16 EIA flange 9 R F TEST 60dBc...

Страница 13: ...ock 6 Set 4 7 GND GND 8 On command 9 Set 1 10 WAIT 11 Reset alarm 12 OFF 13 Interlock 14 N C 15 RF power amplifier current 3 9V x 47 47 94A depending on model 16 Forward Power 3 9Vx1000 1300 2000W dep...

Страница 14: ...1300C 2000LCD ELETTRONICA 4 5 3 Service for programming of factory parameters Type Female DB9 1 NC 2 TX_D 3 RX_D 4 Internally connected with 6 5 GND 6 Internally connected with 4 7 Internally connecte...

Страница 15: ...rall efficiency 60 63 61 Phisical Dimensions W x H x D Weight 32 kg Environmental Working Conditions Cooling OTHER CONNECTORS RF Input RF Output RF Monitor Interlock Output Interlock Input STANDARD CO...

Страница 16: ...escriptions of all hardware and firmware features and capabilities Please see the relevant sections for additional details IMPORTANT When configuring and testing the transmitter in which the equipment...

Страница 17: ...xciter and amplifier RF cable for output to load antenna 50 Ohm coaxial cable with 7 16 EIA flange 5 1 2 Connections Connect the output of a suitable FM exciter for instance PTX30LCD exciter available...

Страница 18: ...r ensuring operator safety and correct operation WARNING The power supply connector is a terminal board Ensure the wire is not live before performing the connection 5 2 First power on and setup Follow...

Страница 19: ...already set to maximum from the Power Setup Menu which you can call up by pressing these keys in the order ESC opens Default Menu ENTER hold down for 2 seconds SET use key to set bar to maximum limit...

Страница 20: ...le Remote mode If you wish to use the telemetry control feature enable Remote control in the Fnc menu see section 5 3 1 for details Note In the Remote mode all local push button controls except Remote...

Страница 21: ...ce press button to increase level press to decrease it When you have achieved the desired level press ENTER to confirm and exit the default menu Please note that the setting is stored automatically in...

Страница 22: ...eview all operating parameters of the machine through the management firmware Normally the machine can run unattended Any alarm condition is handled automatically by the safety system or is signalled...

Страница 23: ...en 7 Men Men Menu Versione Menu Varie Men 9 Men 9 Menu Versione Figure 5 2 When the display is off touching any key will turn on backlighting When the display is on pressing the ESC button from the de...

Страница 24: ...odifies machine operation In the LOCAL mode the machine can read and modify its operating parameters through the navigation keys and the management firmware whereas all other sources are locked out In...

Страница 25: ...power setting go to the default menu menu 1 as outlined earlier 5 4 3 Power Amplifier P A Menu This screen is made up of four lines that can be scrolled using the buttons and shows the readings relati...

Страница 26: ...es into lock out state and the display shows the cause for the stop chap 5 3 4 1 After 15 seconds the machine attempts to re start if a new alarm condition is detected cycle is repeated over and over...

Страница 27: ...power threshold exceeded Alarm 3 Monitoring cycle is as follows An alarm condition occurs Alarm is displayed and device is locked out for 15 sec Operating conditions are restored Verification Upon re...

Страница 28: ...ine set to LOCAL control mode press Reset Alm in the alarm menu menu 7 or power off and back on again using the POWER switch Machine set to REMOTE control mode power off and back on again sending the...

Страница 29: ...address becomes significant when the exciter is connected in an RVR transmission system that uses this protocol Do not change it unless strictly required 5 4 6 Version Menu Vrs This screen holds mach...

Страница 30: ...t easier 6 1 Upper View PJ1000 1300C LCD The figure below shows the upper view of the machine 230V version only one PFC module with the various components pointed out figure 6 1 1 Bias Board 2 Pass Th...

Страница 31: ...User Manual Rev 1 0 28 02 11 6 2 Bottom View PJ1000 1300C LCD The figure below shows the bottom view of the machine with the various components pointed out figure 6 2 1 LED PS Board 2 Inteface Board...

Страница 32: ...CD RF final block SL010RF2002 CPU Panel Display KPANPJCLB06 Secondary cooling fan VTL4184 Main cooling fan VTL4114NH3 Switching power supply KPSL1000 PJ1K PFC block KPFCPSL1000 Interface board SL010IN...

Страница 33: ...nd board layout diagrams are included in the Technical Schedule Vol 2 7 1 PJ1000C 1300C 2000LCD Common Parts 7 1 1 Panel Board The panel board accommodates the microcontroller that runs the machine co...

Страница 34: ...ernally mounted mains fuses and accommodates a bank of surge arresters that protect the machine from any surge events in the power mains Mains voltage is brought from this module to the main Power swi...

Страница 35: ...or traditionals and switching supply Machine is available in different configuration for voltage rectify One PFC solo 230 V Two PFC 115 230 V 7 2 1 1 PFC Unit PFC units are rectifiers that modulates...

Страница 36: ...0C LCD model and is supplied from own switching supply The active device used in the amplifier modules is a Mosfet SD2942 in PJ1300C LCD model or SD2032 in PJ1000C LCD model 7 2 3 LPF card This card i...

Страница 37: ...RF power amplifier modules It is a switching power supply unit with PFC full range for details of the PFC and converter modules 3 Service power supply unit provides adequate power supply for all modu...

Страница 38: ...put power signals in phase so as to keep unbalance and power dissipation to a minimum The whole RF section is mounted on a finned heat sink with fan cooling 7 3 4 LPF Card This board incorporates a lo...

Страница 39: ...ed according to set output power using feedback based on actual output power reading AGC Abnormal conditions affecting bias voltage so as to trigger foldback current limiting are Reflected output powe...

Страница 40: ...36 36 User Manual Rev 1 0 28 02 11 PJ1000C 1300C 2000LCD ELETTRONICA This page was intentionally left blank...

Страница 41: ...____________________________________________________________ ______________________________________________________________________________ ____________________________________________________________...

Страница 42: ...____________________________________________________________ ______________________________________________________________________________ ____________________________________________________________...

Страница 43: ...____________________________________________________________ ______________________________________________________________________________ ____________________________________________________________...

Страница 44: ...104 e mail info rvr it web http www rvr it The RVR Logo and others referenced RVR products and services are trademarks of RVR Elettronica S p A in Italy other countries or both RVR 1998 all rights res...

Отзывы: