background image

 

4

 
 

 
 

Introduction 

 

The R-Tech INV160 is a member of our field acclaimed family of welding products.  
 
Premium features include:

 

1.  Inverter power source – more efficient to operate, provides smoother weld 

characteristics than traditional welders 

2.  Infinite welding voltage to allow fine tuning of weld characteristics 
3.  Adjustable arc force – controls splatter – ideal for automotive work 
4.  Digital amp & volt meters 
5.  Euro type torch fittings for easy torch fitment/replacement 
6.  30% Duty cycle at 160 Amps @ 40C 
7.  60% Duty cycle at 115 Amps @ 40C 
8.  Lightweight and portable – Ideal for maintenance and mobile welders 

 
 

 

Recommended Processes 

 
The R-Tech INV160 is recommended for the MIG welding processes within its output capacity 
of 160 Amps DC 

 
Equipment Limitations  
 

The R-Tech INV160 is protected from overloads beyond the output ratings and duty cycle as 
per machine specifications with thermostat protection of the output coils and rectifiers. 
 
 

Welding Capability – Duty Cycle 
 

The R-Tech INV160 is rated at 160 Amps at 30% and 115 Amps @ 60% duty cycle on a ten 
minute basis. If the duty cycle is exceeded a thermal protector will shut machine off until the 
machine cools. 

 
 

Technical Specifications 

 

Model No. 

 R-Tech MIG INV160 

 

 

 

 

Input 

 

240V AC 50/60Hz 

 

 

 

 

 

 

MIG Operation 

Rated Input Power MAX 

20A MAX 

 

I-Eff Input Power 

11A Continuous 

 

Fuse rating 

13A slow blow 

 

Rated Output Current 

160Amps Max 

 

Generator required KVA 

4.8KVA 

 

Duty Cycle @ 160 AMPS 

30% @ 40

º

 

Duty Cycle @ 115 AMPS 

60% @ 40

º

 

Duty Cycle @ 90 AMPS 

100% @ 40

º

 

Output current Range 

30-160 AMPS 

 

No Load Voltage 

55-75V  

 

Amperage range 0.6mm wire 

30-100 AMPS 

Содержание INV160

Страница 1: ...www r techwelding co uk email sales r techwelding co uk Tel 01452 733933 Fax 01452 733939 INV160 PORTABLE INVERTER MIG WELDER OPERATION INSTRUCTIONS...

Страница 2: ...2...

Страница 3: ...Product MIG INV160 Serial No ___________________________________ Date of Purchase _____________________________ Where Purchased _____________________________ Whenever you request replacement parts or...

Страница 4: ...ithin its output capacity of 160 Amps DC Equipment Limitations The R Tech INV160 is protected from overloads beyond the output ratings and duty cycle as per machine specifications with thermostat prot...

Страница 5: ...m Failure to observe these precautions can result in excessive operating temperatures which can lead to plant failure Grinding Do not direct grinding particles towards the welder An abundance of condu...

Страница 6: ...edback into power lines 4 Interference from re radiation by un grounded metallic objects Keeping these contributing factors in mind installing equipment as per following instructions should minimize p...

Страница 7: ...ically live parts The INV160 Mig Welder requires a 240V 50 60Hz 1 Phase supply It requires a 13A supply It comes with a 3 metre mains cable attached Connect wires according to national coding Brown wi...

Страница 8: ...or and then turn retaining ring clockwise to secure Ensure torch is secured tightly to avoid weld power problems To avoid electric shock keep the Mig torch in good condition and replace if any of the...

Страница 9: ...This feature allows you to record this value along with the preset welding voltage for easy setup to specific job when several different welding jobs are being done 3 Arc Force Gives further adjustmen...

Страница 10: ...by your company 6 Warning LED This warning light will come on under these situations Duty cycle of machine has been exceeded the machine will stop working and the fan will continue to run until machin...

Страница 11: ...too little pressure wire will slip when welding causing unwanted Burnback into tips 3 Wire Feed Drive Assy Make sure rollers are correct size for wire diameter selected to change roller size release...

Страница 12: ...n be dangerous Keep your head out of fumes gases produced from welding Use ventilation or exhaust to remove fumes gases from breathing zone and general area WARNING WELDING SPARKS can cause fire or ex...

Страница 13: ...el wire you have to fit a teflon liner in place of the steel liner in mig torch this is so the wire feeds much smoother and stops it snarling at rollers To fit a teflon liner remove steel liner from t...

Страница 14: ...itchgear Failure to maintain plant can void manufacturers warranty 2 Inspect input and output cables hoses for fraying and cuts replace if damaged present 3 Keep mig torch and earth cables in good con...

Страница 15: ...d Check wire feed unit protecting fuse on rear of machine if blown replace with new fuse of same rating If fuse flows again contact R Tech Machine keeps overheating Warning light is lit on machine Che...

Страница 16: ...16 Wiring Diagram...

Страница 17: ...17...

Страница 18: ...18...

Отзывы: