36
BA_BM_ML-120_EN_12-23.docx
14
Maintenance and Repair
Maintenance and repair work may only be carried out by competent, trained and instructed personnel. If neces-
sary, further operating instructions and/or additional documents must be observed.
After maintenance or repair work on the Mobile Lifter, always carry out a function test.
•
Switch off the main switch before carrying out any maintenance or repair work.
•
WARNING: When opening the battery boxes, there is an acute risk of electric shock at the
pole terminals and other cables, even when the main switch is switched off!
•
Wear safety shoes.
•
Wear suitable protective clothing.
Maintenance and repair work on electrical, pneumatic and mechanical components may only be
carried out by authorised and trained personnel.
Before any maintenance and repair work is carried out, chapter
“Safety” must be read
carefully and observed!
14.1
General Maintenance Intervals
Interval Activity
Daily
Remove coarse dirt. Check all components for damage and have them replaced by quali-
fied personnel if necessary. Customer service (phone: 0049 7576 / 962 978 - 0).
Monthly
Slightly lubricate castors, pallet truck rollers, clamping lever threads and bearing points.
Annual
Check the wire rope for visible damage (cracks, fraying, etc.).
If there is any damage, stop the mobile lifter and contact the customer service.
Every 1.5 years
For safe operation, the Mobile Lifter must be inspected. Please contact our customer
service for this (phone: 0049 7576 / 962 978 - 0).
14.2
Check Mechanical Equipment
•
Regularly check all screw connections and whether all wheels are correctly fastened.
•
If necessary, retighten loose screw connections with a suitable spanner.
•
Regularly check the function and ease of movement of the clamping levers and locking pins.
•
Regularly check that there are no breaks or cracks in weld seams.
14.3
Check Electrical Equipment
•
Regularly check the functions of the electrical equipment.
•
Regularly check that there are no loose or pinched cables.
•
Have damaged cables repaired by competent electrical personnel.
•
The two supply batteries are maintenance-free. Therefore, no checking or refilling of water is necessary.
The batteries only need to be kept dry and clean.
•
Only use original spare parts when replacing them! Otherwise the warranty claim will be invalidated.
14.4
Check Pneumatic Equipment
•
Regularly check all hoses, connections and fittings for defects and leaks.
•
Regularly check all hoses for proper and trip-free routing as well as kinks.
•
Regularly check the proper functioning of the valves on the vacuum pads.