Detector Maintenance and Battery Replacement

Check the operational capability of the DoorProtect detector on a regular basis.

Clean the detector body from dust, spider web and other contaminations as they
appear. Use soft dry napkin suitable for equipment maintenance.

Do not use any substances containing alcohol, acetone, gasoline and other
active solvents for cleaning the detector.

The battery lifetime depends on battery quality, actuation frequency of the
detector and ping interval of the detectors by the hub.

If the door opens 10 times a day and the ping interval is 60 seconds, then
DoorProtect will operate up to 7 years from the pre-installed battery. Setting the
ping interval of 12 seconds, you will reduce the battery life to 2 years.

If the detector battery is discharged, you will receive a noti cation, and the LED
will smoothly light up and go out, if the detector or tamper is actuated.

Tech specs

Battery Replacement

Содержание DoorProtect

Страница 1: ... It consists of ferromagnetic contacts placed in a bulb that form a continuous circuit under the effect of a constant magnet DoorProtect operates within the Ajax security system connecting via the protected radio protocol Communication range is up to 1 200 m in the line of sight Using the or integration modules DoorProtect can be used as part of third party security systems The detector is set up ...

Страница 2: ...ements Operating Principle Buy opening detector DoorProtect 1 DoorProtect 2 Big magnet 3 Small magnet 4 LED indicator 5 SmartBracket attachment panel perforated part is required for actuating the tamper in case of any attempt to dismantle the detector Don t break it out 6 External detector connection socket 7 QR code 8 Device switch 9 Tamper button ...

Страница 3: ... works at a distance of 1 cm and the big one up to 2 cm After actuation DoorProtect immediately transmits the alarm signal to the hub activating the sirensand notifying the user and security company Pairinging the Detector Before starting pairing Only users with administor rights can add the device to the hub How to pair the detector with the hub 1 Following the hub instruction recommendations ins...

Страница 4: ...b at a single protected object The request for connection to the hub is transmitted for a short period of time at the moment of switching on the device 2 Name the device scan write manually the QR Code located on the body and packaging and select the location room 3 Select Add the countdown will begin 4 Switch on the device ...

Страница 5: ... of the detectors statuses in the list depends on the detector ping interval set in the hub settings he default value is 36 seconds Connecting to Third Party Systems To connect the detector to a third party security central unit using the or integration modules follow the recommendations in the user manual of the respective device States uartBridge ocBridge Plus 1 Devices 2 DoorProtect ...

Страница 6: ...s of 25 Lid The tamper state which reacts to detachment or damaging of the detector body Delay When Entering sec The delay time when entering Delay When Leaving sec The delay time when exiting Routed Through Rex Indicates if the detector is routed through a radio signal range extender Primary Detector The primary detector status Secondary Detector The status of the external detector connected to D...

Страница 7: ...Setting Up Setting Value First eld The detector name can be edited 1 Devices 2 DoorProtect 3 Settings ...

Страница 8: ...is open If active and are activated when the opening detected Activate the siren if an external contact opened If active HomeSiren and StreetSiren are activated during an external detector alarm Jeweller Signal Strength Test Switches the detector to the signal strength test mode Detection Zone Test Switches the detector to the detection area test Attenuation Test Switches the detector to the signa...

Страница 9: ...n Jeweller settings in hub settings Installing the Detector Selecting the location Location of DoorProtect is determined by its remoteness from the hub and presence of any obstacles between the devices hindering the radio signal transmission walls inserted oors large objects located within the room Check the signal level at the installation location If the signal level is low one bar we cannot gua...

Страница 10: ...and detector should not exceed 1 cm When positioning the parts of DoorProtect in the same plane use the big magnet Its actuation threshold 2 cm Attach the magnet to the moving part of the door window to the right of the detector If necessary the detector may be overturned or positioned horizontally Installing the detector Before installing the detector make sure that you have selected the optimal ...

Страница 11: ...he device may fail from a hit 2 Put the detector on the attachment panel As soon as the detector is xed in SmartBracket it will blink with a LEDsignaling that the tamper is closed If the light indicator do not blink after installing in SmartBracket check the status of the tamper in the Ajax app and then the xing tightness of the panel If the detector is torn off from the surface or removed from th...

Страница 12: ... to install a wired detector at a distance not exceeding 1 meter increasing the wire length will increase the risk of its damage and reduce the quality of communication between the detectors To lead out the wire from the detector body break out the plug 3 inside any premises with the temperature and humidity beyond the permissible limits 4 closer than 1 m to the hub ...

Страница 13: ...e and other active solvents for cleaning the detector The battery lifetime depends on battery quality actuation frequency of the detector and ping interval of the detectors by the hub If the door opens 10 times a day and the ping interval is 60 seconds then DoorProtect will operate up to 7 years from the pre installed battery Setting the ping interval of 12 seconds you will reduce the battery life...

Страница 14: ...l range Up to 1 200 m any obstacles absent Power supply 1 battery CR123A 3 V Battery life Up to 7 years Operating temperature range From 10 С to 40 С Operating humidity Up to 75 Dimensions Ø 20 90 mm Weight 29 g Certi cation Security Grade 2 Environmental Class II in conformity with the requirements of EN 50131 1 EN 50131 2 6 EN 50131 5 3 Complete Set Hub Hub Plus Hub 2 ReX ocBridge Plus uartBridg...

Страница 15: ...alid for 2 years after the purchase and does not apply to the pre installed battery If the device does not work correctly you should rst contact the support service in half of the cases technical issues can be solved remotely 7 Installation kit 8 Quick Start Guide The full text of the warranty ...

Отзывы: