Safety of lithium batteries
Certain heat meter components can be equipped with a lithium
battery.
This type of battery is classified as hazardous.
VALID TRANSPORT REGULATIONS ARE TO BE ADHERED TO IN EACH
CASE! Inspection documents for the batteries used are available on request.
Handling lithium batteries
• store protected from dampness and moisture
•
do not heat to above 100 °C or throw in fire
• do not short-circuit
• do not open or damage
• do not charge
• do not store within reach of children
In the event of an accident, the following points must be heeded:
In the case of a leak:
- cover with sodium carbonate or an equivalent crystal soda
- make gases and vapours precipitate by spraying with water
- make sure of sufficient ventilation
- avoid any direct contact
In the event of injuries:
- If interior components of the dry element should come into contact with the
eyes, rinse thoroughly with water for 15 minutes.
- In the event of contact with the skin, wash with plenty of water and take off
soiled clothing.
- Move away from the accident spot following inhalation.
- Always consult a doctor.
In the event of a fire:
- Use a Lith-X or Class-D fire extinguisher.
- NEVER USE WATER FOR EXTINGUISHING PURPOSES
- Do not use CO
2
, halogen fire extinguishers with dry substances or foam
extinguishers.
- Move away from the accident spot following inhalation and ventilate the area.
- Always consult a doctor.
Safety notes for lithium batteries
Technical data
CE conformity
see Declaration of Conformity
Electromagnetic compatibility
Interference resistance
EN 61000-6-2
Emitted interference
EN 61000-6-3
Protection rating
IP protection rating Calculator unit
Flow sensor
IP65 according to EN 60529
IP65 according to EN 60529
Heat meters
European Measuring Instruments Directive (MID)
EC type examination certificate
2004/22/EC
DE-14-MI004-PTB006
Heat meters
Model
EN1434
HMR5-xxAx-xxx0 xxxxx
Quality of heat medium
in accordance with VDI guideline 2035
in accordance with AGFW-Norm 510
Influencing quantities
Electromagnetic class
E1
Mechanical class
M2
Environment class
A
Precision class
3
Norms and standards
Temperature range
as heat meter
20 °C ... 90 °C
permissible temperature difference
start of metering temperature differ-
ence
3 K - 160 K
1.0 K
Ambient temperature
5 °C ... 55 °C
Power supply
Lithium battery
Nominal voltage 3.0 V
Service life
> 6 (opt. 10) years + 6 months reserve
Display levels
Standard
min. 2, up to 6
(depending on the version and options included)
Display
8-digit LCD + pictograms
Energy display
kWh (opt. MWh, MJ, GJ)
Calculator unit