background image

14

15

Display

Display level L9 – Current values

alt.

alt.

Max. temperature

Date

Period above limiting 

value

Max. flow rate

Period > qp

Date

alt.

alt.

alt.

alt.

Displays 

the level

Supply flow

Return flow

WMZ

Special operating states

Display

Description

Measures/Notes

•  Communication credit of the 

module interface or IrDA 

exceeded

•  Is eliminated after the credit pe-

riod (module = current day; IrDA 

= current month) has been reset 

automatically by the device

•  The battery life has 

expired.

•  Device must be replaced

• 

Wrong direction of flow

•  Check installation (note arrow on 

flow sensor)

•  Check piping

•  Check recirculating pumps and 

thermostats for correct function

•  Temperature sensors may 

have been mixed up or fitted 

incorrectly

• 

Check whether flow sensor has 

been fitted in the right strand or 

•  check type of installation of 

temperature sensor

•  Air in the measuring section

•  No correct ultrasonic meas-

uring signal

•  Bleed the pipe system

Error messages

Display

Error display

Error description

Measures/Notes

•  Hardware error or 

damaged firmware

• 

Check flow sensor, connection 

cable and calculator unit for external 

damage

•  Device must be replaced

•  Add-on module was 

paired with another 

meter before

•  The module has the measuring data 

of another heat meter

•  Save data, since these are overwrit-

ten after a short time

•  Press any key to delete the display

• 

Supply flow

 

sensor broken

•  Check temperature sensor and pipes 

for mechanical damage

•  Device must be replaced

•  Short circuit 

supply flow sensor

•  Check temperature sensor and pipes 

for mechanical damage

•  Device must be replaced

• 

Return flow

 

sensor broken

•  Check temperature sensor and pipes 

for mechanical damage

•  Device must be replaced

•  Short circuit 

return flow sensor

•  Check temperature sensor and pipes 

for mechanical damage

•  Device must be replaced

Содержание Q heat 5 Ultrasonic

Страница 1: ...1 Q heat 5 Ultrasonic Heat meters Operating manual IMPORTANT READ THROUGH CAREFULLY BEFORE USE KEEP ACCESSIBLE THROUGHOUT THE PRODUCT LIFETIME ...

Страница 2: ...r handling and excessively forceful tightening of screwed connections can cause leaks Observe the maximum torque stated in the manual The dimensions and thermal loads of seals must be appropriate for their application You should therefore only use the seals delivered with the device Only use water without chemical additives as the medium for this device The installed meter is a pressurized compone...

Страница 3: ...USE WATER FOR EXTINGUISHING PURPOSES Do not use CO2 halogen fire extinguishers with dry substances or foam extinguishers Move away from the accident spot following inhalation and ventilate the area Always consult a doctor Safety notes for lithium batteries Technical data CE conformity see Declaration of Conformity Electromagnetic compatibility Interference resistance EN 61000 6 2 Emitted interfere...

Страница 4: ...ess the H key or press the V key 2 To change from any position on one level to the next level Press the H key 3 To change to the next display within one level Press the V key Flow sensor Temperature sensor Measuring element PT 1000 according to EN 60751 Version Type DS Diameter 5 0 mm 5 2 mm Type of installation 5 0 mm direct ball valve indirect immersion sleeve 5 2 mm direct ball valve indirect i...

Страница 5: ...ate are displayed be fore the meter status If the incorrect direction of flow is established an error message appears on the display as shown Operating scheme Display L0 L1 L2 L3 L5 L9 Current consumption values Standard level Annual consumption values Standard level Current values Can be hidden individually Parameter Can be hidden individually Monthly values heat Can be switched off individually ...

Страница 6: ... date Checksum alt alt alt The displays coloured grey are optional or can be added and switched off as required Annual consumption values Heat Display Display level L2 Current values alt Displays the level Current flow Current supply flow temperature Current return flow temperature Current temperature difference Current energy flow Operating hours Cumulated volume High resolution meter status heat...

Страница 7: ... and 8 not available level 9 hidden Calibrated checksum firmware version Serial number Calibrated firmware version alt alt Display Display level L5 Monthly values heat Displays the level Oldest monthly value heat alt alt alt Latest monthly value heat alt alt alt Date Serial number Checksum Meter status The displays coloured grey are optional or can be added and switched off as required ...

Страница 8: ... of installation of temperature sensor Air in the measuring section No correct ultrasonic meas uring signal Bleed the pipe system Error messages Display Error display Error description Measures Notes Hardware error or damaged firmware Check flow sensor connection cable and calculator unit for external damage Device must be replaced Add on module was paired with another meter before The module has ...

Страница 9: ...098 Erfurt Tel 49 0 3 61 26 280 0 Fax 49 0 3 61 26 280 175 www qundis com Ultrasonic heat meter Operating manual Q heat 5 US Type Ultrasonic measuring technology Document no FOM5ZZHEEN0 USDSP Date published 5 12 2014 Version V3 00 ...

Отзывы: