Display

Display level L3 – Parameters

Displays the level

Date of next due date

Identification

Po activated 

levels

This example: 

Levels 2, 3 and 5 are shown, 

4 x space = levels 4, 6, 7 and 8 

not available, 

 = level 9 hidden

Calibrated checksum

firmware version

 

Serial number

Calibrated

firmware version

alt.

alt.

Display

Display level L5 – Monthly values heat

Displays the level

Oldest monthly 

value heat

alt.

alt.

alt.

Latest monthly value

heat

alt.

alt.

alt.

Date 

Serial number

Checksum

Meter status 

The displays coloured grey are optional or can be added and 

switched of

f as required

 

Содержание Q heat 5 Ultrasonic

Страница 1: ...1 Q heat 5 Ultrasonic Heat meters Operating manual IMPORTANT READ THROUGH CAREFULLY BEFORE USE KEEP ACCESSIBLE THROUGHOUT THE PRODUCT LIFETIME ...

Страница 2: ...r handling and excessively forceful tightening of screwed connections can cause leaks Observe the maximum torque stated in the manual The dimensions and thermal loads of seals must be appropriate for their application You should therefore only use the seals delivered with the device Only use water without chemical additives as the medium for this device The installed meter is a pressurized compone...

Страница 3: ...USE WATER FOR EXTINGUISHING PURPOSES Do not use CO2 halogen fire extinguishers with dry substances or foam extinguishers Move away from the accident spot following inhalation and ventilate the area Always consult a doctor Safety notes for lithium batteries Technical data CE conformity see Declaration of Conformity Electromagnetic compatibility Interference resistance EN 61000 6 2 Emitted interfere...

Страница 4: ...ess the H key or press the V key 2 To change from any position on one level to the next level Press the H key 3 To change to the next display within one level Press the V key Flow sensor Temperature sensor Measuring element PT 1000 according to EN 60751 Version Type DS Diameter 5 0 mm 5 2 mm Type of installation 5 0 mm direct ball valve indirect immersion sleeve 5 2 mm direct ball valve indirect i...

Страница 5: ...ate are displayed be fore the meter status If the incorrect direction of flow is established an error message appears on the display as shown Operating scheme Display L0 L1 L2 L3 L5 L9 Current consumption values Standard level Annual consumption values Standard level Current values Can be hidden individually Parameter Can be hidden individually Monthly values heat Can be switched off individually ...

Страница 6: ... date Checksum alt alt alt The displays coloured grey are optional or can be added and switched off as required Annual consumption values Heat Display Display level L2 Current values alt Displays the level Current flow Current supply flow temperature Current return flow temperature Current temperature difference Current energy flow Operating hours Cumulated volume High resolution meter status heat...

Страница 7: ... and 8 not available level 9 hidden Calibrated checksum firmware version Serial number Calibrated firmware version alt alt Display Display level L5 Monthly values heat Displays the level Oldest monthly value heat alt alt alt Latest monthly value heat alt alt alt Date Serial number Checksum Meter status The displays coloured grey are optional or can be added and switched off as required ...

Страница 8: ... of installation of temperature sensor Air in the measuring section No correct ultrasonic meas uring signal Bleed the pipe system Error messages Display Error display Error description Measures Notes Hardware error or damaged firmware Check flow sensor connection cable and calculator unit for external damage Device must be replaced Add on module was paired with another meter before The module has ...

Страница 9: ...098 Erfurt Tel 49 0 3 61 26 280 0 Fax 49 0 3 61 26 280 175 www qundis com Ultrasonic heat meter Operating manual Q heat 5 US Type Ultrasonic measuring technology Document no FOM5ZZHEEN0 USDSP Date published 5 12 2014 Version V3 00 ...

Отзывы: