Instruction book
2920 7101 22
117
10.2.4.2 Before starting
Status icons for each compressor on the main screen of the master regulator.
Icon
Status
Description
No valid compressor type
An unknown compressor type is detected
No communication
Fixed Speed or VSD: No reply from the connected
compressor within a time out. Electro pneumatic
compressor: Status red from the compressor is not
consistent or illogical.
No answer
Connected compressor is not responding ( or not
responding correctly) to the commands. (example: no
reaction on a load command)
Not available
Compressor is stopped and is counting out the Minimum
Stop Time. During this time the compressor is Not
Available to the ECOntrol6 algorithm.
Shutdown
Compressor is in Shutdown condition
Stopped / Running
The compressor is running local
Input icons for each compressor on the main screen of the master regulator.
Icon
Description
Frequency converter driven compressor
Unload compressor
Load compressor
When the ECO6 is controlling the connected units, the icon is rotating
10.2.4.3 Starting
After pressing the start button, the ECOi regulator will start, load, unload and stop the compressors needed
to keep the net pressure between the programmed pressure bands, while taking into account the
programmed ECOi parameters.