9.3 Compressor
data
Reference conditions
Gearbox driven units
All data specified below apply under reference conditions, see section
Reference
conditions and limitations
.
Units
7.5 bar
8 bar
10 bar
13 bar
100 psi
125 psi
150 psi
175 psi
Frequency
Hz
50 50 50 50 60 60 60 60
Nominal working
pressure
bar(e)
7 8 9.5 12.5 6.9 8.6 10.3 12
psig
102 116 138 181 100 125 150 175
Maximum working
pressure
bar(e)
7.5 8 10 13 7.4 9.1 10.8 12.5
psig
109 116 145 189 107 132 157 181
Unloading pressure
Maximum setting
bar(e)
7.2 8.2 9.7 12.7 7.1 8.8 10.5 12.2
psig
104 119 141 184 103 128 152 177
Unloading pressure
Factory setting
bar(e)
7 8 9.5 12.5 6.9 8.6 10.3 12
psig
102 116 138 181 100 125 150 175
Unloading pressure
Minimum setting
bar(e)
4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1
psig 59.5 59.5 59.5 59.5 59.5 59.5 59.5 59.5
Loading pressure
Maximum setting
bar(e)
7.1 8.1 9.6 12.6 7 8.7 10.4 12.1
psig
103 117.5
139 183 101.5
126 151 175.5
Loading pressure
Factory setting
bar(e)
6.4 7.6 8.9 11.9 6.3 8 9.7 11.4
psig
93 110 129 173 91 116 141 165
Loading pressure
Minimum setting
bar(e)
4 4 4 4 4 4 4 4
psig
58 58 58 58 58 58 58 58
Set point,
thermostatic valve
˚
C
40 40 40 65 40 40 40 65
˚
F 104 104 104 149 104 104 104 149
Units
7.5 bar
8 bar
10 bar
13 bar
100 psi
125 psi
150 psi
175 psi
Set point,
thermostatic valve
(converter)
˚
C
65 65 65 65 65 65 65 65
˚
F 149 149 149 149 149 149 149 149
Power
hp
40
50
60
75
100
100
125
150
Refrigerant type,
units with Dryer
R404a R404a R410a R410a N/A
N/A
N/A
N/A
Total amount
(refrigerant), units
with Dryer
kg 1.3 1.3 2.05 2.05 — — — —
Oil capacity, air-
cooled units
l 20 20 20 30 31 33 33 42