background image

Page 13 

 

 

 

 

Fast flash 

Configured, 
sensing 
current data, 
sensing 
voltage data 

 

 

Fast flash 

Current and 
volt logger 
only… 

 

Configured, 
not sensing 
valid data 

Troubleshooting: Check installation 

Time out: 

5 minutes 

 

LED diagnostics will remain ON for 5 
minutes after the key is pressed 

 

4.2.8  Data logger installation 

 

Prior to installation make sure that data 
loggers are configured using the Audit Wizard 
feature at quincy.scadar.net. 

 

Print and retain the audit configuration check 
list before attending the audit location! 

 

Download the audit configuration from 
quincy.scadar.net to your EQ LTE™ base 
station 

 

Transfer the audit configuration from your EQ 
LTE™ base station to each EQ LTE™ data 
logger 

 

Ensure that each data logger is installed to the 
assigned audit location (e.g. air compressor 
brand, model and or serial number or pressure 
point) 

 

4.2.9  EQ LTE™ current & volt data logger 

 

4.2.9.1  Technical data: 

 

Identification: 

EQ LTE™ Logger, current & volts 

 

2014900356 

EQ LTE™ 

EQ LTE™ current & volts 

data logger 

Precision data logging 

Part number: 
Product family: 
Definition: 

Function: 

 

Data logger: 

 

A / D resolution: 

16 bit 

Battery life: 

2 calendar years or more 

(est.) 

Bluetooth (slave): 

2.1 + EDR (enhanced data 

rate) 

Bluetooth range: 

10 meters (33 feet) 

The effective range varies due to propagation 

conditions, material coverage, production 

 

 
 
 

sample variations, antenna configurations and 

battery conditions 

Operating temp: 

0°C ~ +55°C (+32°F ~ 

+131°F) 

Power / batteries: 

Four AA lithium primary cells, 

Li/SOCI2, 3.6V, 2700mAh 

Real time clock: 

Precision real time clock 

(temp compensated crystal) 

Maximum deviation: 

0.4s / day 

Sample capacity: 

More than 1.4 million samples 

(16 days continuous logging) 

Sample frequency: 

1 second (fixed resolution) 

Software: 

Pre-programmed application 

software 

Current sensor: 

 

AC voltage: 

Range: 100 V to 700 V 

Accuracy: 1% 

AC current: 

Range: 10 Amp ~ 800Amp 

Accuracy: 

1% 

Max nondestructive 
current: 

2000 A 

Ambient temperature 
influence on accuracy: 

<0.1% per 1°C for 

temperatures from -10°C to 

+18°C and from 28°C to 50°C 

Rise / fall time: 

< 400ms 

Burden resistance: 

≤1 ohm

 

Operating temp: 

-10°C ~ +50°C (+14°F ~ 

+122°F) 

Storage temp: 

-40°C to +70°C (-40°F to 

+160°F) 

Safety rating: 

CAT III 600V 

Useable frequency: 

10Hz – 100 kHz 

Dimensions: 

216mm (8.5”) x 111mm (4.4”) 

x 45mm (1.8”) 

Jaw capacity: 

52mm (2.05 inch) 

Weight 

0.65kg (1.4lb) 

Conformity: 

 

Drop test: 
Mech and shock test: 

IEC61010-031: 2008 

IEC61010-1: 2010 

IEC 68-2-32 @ 1 meter 

IEC 68-2-27 @ 100G 

Regulatory mark: 

CE, UL 

Volt measurement and test lead set: 

Measuring device: 

Alligator clip set (2) 

 

Red & black pair of small, 

insulated, nickel plate jaws 

 

Blunt tip grabs round screw 

heads up to 9.5mm 

 

CAT IV 600V, CAT III 1000 V, 

10A rating 

Test lead set: 

Red & black with safety 

shrouded, standard diameter 

banana plugs 

 

Right angle connector on one 

end and straight connector on 

the other 

Reinforced strain relief 

1.5metre silicone-insulated 

wire resists heat & cold 

 

CAT IV 600V, CAT III 1000 V, 

10A rating 

Conformity: 

EN 61010-1-032 

73/23/EEC, Low voltage 

(amended 93/68/EEC) 

Regulatory mark 

CE, UL 

 

Содержание EQ LTE 2014900479

Страница 1: ...Equipment Technical Manual Base Station...

Страница 2: ...wer Supply 100 240vAC input DC output power supply c w plug assortment Note No case is supplied with this kit items are supplied loose EQ LTE Logger Pressure 0 16BAR complete case kit 2014900357 20149...

Страница 3: ...t Logger assembly EQ LTE Sensor moisture dewpoint EQ LTE Sensor moisture dewpoint mounting chamber EQ LTE Power Supply 100 240vAC input DC output power supply c w plug assortment EQ LTE Logger 4 20mA...

Страница 4: ...st use 4 2 4 General operation 4 2 5 Power supply 4 2 6 Logger battery compartment 4 2 7 Keypad 4 2 7 1 Bluetooth key and LED 4 2 7 2 Diagnostic key and LED 4 2 8 Data logger installation 4 2 9 EQ LTE...

Страница 5: ...hat an organization or website is referred to in this work as a citation and or a potential source of further information does not mean that the author or the publisher endorses the information the or...

Страница 6: ...he licensed materials including the specific design and structure of individual programs constitute trade secrets and or copyrighted material of Quincy Compressor Customer agrees not to disclose provi...

Страница 7: ...the device personnel must use relevant safe working practice and observe all relevant local health and safety requirements and regulations Lethal voltages may be present at or around the device Elect...

Страница 8: ...the ratings supply voltage frequency pressure temperature altitude humidity and environmental rating for which it is designed Do not operate the device without battery door enclosure open or covers r...

Страница 9: ...ated The very latest Bluetooth technology then enables this information to be effortlessly transferred from multiple data loggers to a single intelligent EQ LTE base station In turn the base station t...

Страница 10: ...g device ID serial number and original equipment manufacturer bar code data is located on the back elevation of the base station 4 1 2 Preparing for first use Each EQ LTE base station is supplied with...

Страница 11: ...onment and EQ LTE data loggers Once EQ LTE data loggers return from the audit location simply synchronize with the EQ LTE base station once more and transfer your logged data from the EQ LTE base stat...

Страница 12: ...Wizard configuration files from base station to logger s using Bluetooth Base to logger s Distributing logger configuration files to loggers Logger s to base Used to transfer data files from logger s...

Страница 13: ...t locks either side of carry handle Transportation feet for stability when stacked Formed cushion insert Tamper resistant label providing device ID serial number and original equipment manufacturer ba...

Страница 14: ...data loggers also feature an external power supply input This is used to power the data logger sensor Note The use of an external power supply unit does not eliminate the use of or need for the data...

Страница 15: ...Slow flash Not configured Troubleshooting Create audit configuration transfer from cloud to base station and then from base station to logger Fast flash Configured not sensing data Troubleshooting Ch...

Страница 16: ...ing temp 0 C 55 C 32 F 131 F Power batteries Four AA lithium primary cells Li SOCI2 3 6V 2700mAh Real time clock Precision real time clock temp compensated crystal Maximum deviation 0 4s day Sample ca...

Страница 17: ...wet environments Do not use the device if it operates incorrectly Protection can be compromised Examine the test leads for damaged insulation or exposed metal Check test lead continuity Replace damage...

Страница 18: ...deviation 0 4s day Sample capacity More than 1 4 million samples 16 days continuous logging Sample frequency 1 second fixed resolution 4 2 10 2 Sensor installation Warning risk high pressure Isolate...

Страница 19: ...and should be chosen according to practical constraints Observe and maintain safe working practices at all times Identification EQ LTE Logger temperature 2014900365 EQ LTE EQ LTE Temperature data log...

Страница 20: ...point data logger Precision data logging Definition Function Logger A D resolution 16 bits Bluetooth slave 2 1 EDR enhanced data rate Bluetooth range 10 meters 33 feet The effective range varies due t...

Страница 21: ...ets at the sensor element Condensation or water on the sensor element may cause a fault and may corrupt sensor data The size of the inlet and outlet pipe diameter sections must not be less than the sp...

Страница 22: ...present in area L of the diagram below Be aware that the air flow sensor is directional L Length of pipe section At inlet L1 15 x inner pipediameter At outlet L2 5 x inner pipe diameter D Inner diamet...

Страница 23: ...39 69 Oxygen O2 176 4 578 74 Nitrous oxide N2O 181 4 595 14 Natural gas NG 109 4 358 92 DIN 1343 0 C 1013 25mbar Maintenance The sensor head should be checked regularly for dirt and cleaned if necessa...

Страница 24: ...slave 2 1 EDR enhanced data rate Bluetooth range 10 meters 33 feet The effective range varies due to propagation conditions material coverage production sample variations antenna configurations and b...