background image

Page 8 

 

 

 

 

Finally, and only after an internet connection 
has been established; perform a base station 
update as described in this manual. 

 

Your EQ LTE™ base station is ready for use! 

 

Notes: 

EQ LTE™ base stations use 

 

conventional DHCP or manual IP 
configuration methods. 

 

The manufacturers do not provide 
support relating to the use of 
ancillary products such as WIFI 
dongles. 

 

Network security restrictions may 
prevent the EQ LTE™ base station 
from accessing the internet 

 

If you experience internet connection 
difficulties, contact your local IT 
administrator in the first instance! 

 

4.1.3 General operation 

 

A EQ LTE™ base station provides users with a 
‘PC free’ solution for the handling of data 
between the quincy.scadar.net cloud 
computing environment and EQ LTE™ data 
loggers 

 

The EQ LTE™ base station allows users to 
download audit configurations from the 
quincy.scadar.net cloud computing 
environment, wirelessly synchronize audit 
configurations with up to 20 EQ LTE™ data 
loggers, wirelessly retrieve logged data from 
up to 20 EQ LTE™ data loggers and return 
logged data to the quincy.scadar.net cloud 
computing environment. 

 

Once audit configurations are synchronized, 
EQ LTE™ data loggers can log data without 
the need for any further connection with the 
EQ LTE™ base station. 

 

Although identical in size and rugged in 
design, the EQ LTE™ base station is not 
intended to accompany data loggers to the 
audit location. More typically, the 
EQ LTE™ base station will remain connected 
to an office local area network with internet 
access and act as an instantly accessible 
portal for the transfer of data between the 
quincy.scadar.net cloud computing 
environment and EQ LTE™ data loggers. 

 

Once EQ LTE™ data loggers return from 

the audit location, simply synchronize with the 
EQ LTE™ base station once more and 
transfer your logged data from the EQ LTE™ 
base station to the quincy.scadar.net cloud 
computing environment. 

 

Only one EQ LTE™ base station is required to 
manage data between the quincy.scadar.net 
cloud computing environment and an infinite 
number of EQ LTE™ data loggers. 

 

4.1.4 Technical data 

 
 

Function: 

Handles data between EQ LTE™ 

data loggers and the quincy.scadar.net 

cloud computing environment 

2014900359 

IP20 

(W x H x D): 98 x 203.2 x 34.8mm 

(0.32 x 0.66 x 0.11 ft) 

0.31 kg (11 ounces) 

Ethernet:CAT5e 10/100Mbps 

RJ45 

LED A: flashes to indicate 

communications 

LED B: On when 100Mbps connection 

is detected 

Off when 10Mbps is active 

USB type B (not used) 

Input power: 

100 – 240V AC 

50 – 60Hz 

0.6 A 

Supplied with EU, UK & US AC heads 

as standard 

Output power: 24vDC 

0.75Amp 

1.8M (5 foot) jack lead 

3.5” color ¼VGA 

 

Part Number 
IP rating: 
Dimensions: 

Weight: 
Connection: 

 
 

USB: 
Power: 

 
 

 

Graphic display: 

Keypad: 

5 tactile key, membrane switch panel 

construction 

Bluetooth: 

V2.1 + EDR (enhanced data rate) 

master device with capacity to 

simultaneously communicate with up to 

20 slave data loggers 

Bluetooth 
range: 

10 meters (33 ft) 

 

The effective range varies due to propagation conditions, 

material coverage, production sample variations, antenna 

configurations and battery conditions 

Software 

Pre programmed application software 

configurable via OUI 

Languages: 

N/A 

Display 
symbols: 

ISO7000 and custom 

Approvals: 

CE, FCC 

Operating temp: 

0°C ~ +40°C (+32°F ~ +104°F) 

Storage temp: 

-25°C ~ +70°C (-13°F ~ +158°F) 

Relative 
humidity: 

<95% condensation @ 40°C (104°F) 

without condensation 

 

4.1.5 Power supply 

 

The EQ LTE™ Base Station is powered 
from an external power supply which can be 
operated from a regular ‘domestic’ power 
supply.

Operating voltage: 

90 - 264 Vac 

 

Содержание EQ LTE 2014900479

Страница 1: ...Equipment Technical Manual Base Station...

Страница 2: ...wer Supply 100 240vAC input DC output power supply c w plug assortment Note No case is supplied with this kit items are supplied loose EQ LTE Logger Pressure 0 16BAR complete case kit 2014900357 20149...

Страница 3: ...t Logger assembly EQ LTE Sensor moisture dewpoint EQ LTE Sensor moisture dewpoint mounting chamber EQ LTE Power Supply 100 240vAC input DC output power supply c w plug assortment EQ LTE Logger 4 20mA...

Страница 4: ...st use 4 2 4 General operation 4 2 5 Power supply 4 2 6 Logger battery compartment 4 2 7 Keypad 4 2 7 1 Bluetooth key and LED 4 2 7 2 Diagnostic key and LED 4 2 8 Data logger installation 4 2 9 EQ LTE...

Страница 5: ...hat an organization or website is referred to in this work as a citation and or a potential source of further information does not mean that the author or the publisher endorses the information the or...

Страница 6: ...he licensed materials including the specific design and structure of individual programs constitute trade secrets and or copyrighted material of Quincy Compressor Customer agrees not to disclose provi...

Страница 7: ...the device personnel must use relevant safe working practice and observe all relevant local health and safety requirements and regulations Lethal voltages may be present at or around the device Elect...

Страница 8: ...the ratings supply voltage frequency pressure temperature altitude humidity and environmental rating for which it is designed Do not operate the device without battery door enclosure open or covers r...

Страница 9: ...ated The very latest Bluetooth technology then enables this information to be effortlessly transferred from multiple data loggers to a single intelligent EQ LTE base station In turn the base station t...

Страница 10: ...g device ID serial number and original equipment manufacturer bar code data is located on the back elevation of the base station 4 1 2 Preparing for first use Each EQ LTE base station is supplied with...

Страница 11: ...onment and EQ LTE data loggers Once EQ LTE data loggers return from the audit location simply synchronize with the EQ LTE base station once more and transfer your logged data from the EQ LTE base stat...

Страница 12: ...Wizard configuration files from base station to logger s using Bluetooth Base to logger s Distributing logger configuration files to loggers Logger s to base Used to transfer data files from logger s...

Страница 13: ...t locks either side of carry handle Transportation feet for stability when stacked Formed cushion insert Tamper resistant label providing device ID serial number and original equipment manufacturer ba...

Страница 14: ...data loggers also feature an external power supply input This is used to power the data logger sensor Note The use of an external power supply unit does not eliminate the use of or need for the data...

Страница 15: ...Slow flash Not configured Troubleshooting Create audit configuration transfer from cloud to base station and then from base station to logger Fast flash Configured not sensing data Troubleshooting Ch...

Страница 16: ...ing temp 0 C 55 C 32 F 131 F Power batteries Four AA lithium primary cells Li SOCI2 3 6V 2700mAh Real time clock Precision real time clock temp compensated crystal Maximum deviation 0 4s day Sample ca...

Страница 17: ...wet environments Do not use the device if it operates incorrectly Protection can be compromised Examine the test leads for damaged insulation or exposed metal Check test lead continuity Replace damage...

Страница 18: ...deviation 0 4s day Sample capacity More than 1 4 million samples 16 days continuous logging Sample frequency 1 second fixed resolution 4 2 10 2 Sensor installation Warning risk high pressure Isolate...

Страница 19: ...and should be chosen according to practical constraints Observe and maintain safe working practices at all times Identification EQ LTE Logger temperature 2014900365 EQ LTE EQ LTE Temperature data log...

Страница 20: ...point data logger Precision data logging Definition Function Logger A D resolution 16 bits Bluetooth slave 2 1 EDR enhanced data rate Bluetooth range 10 meters 33 feet The effective range varies due t...

Страница 21: ...ets at the sensor element Condensation or water on the sensor element may cause a fault and may corrupt sensor data The size of the inlet and outlet pipe diameter sections must not be less than the sp...

Страница 22: ...present in area L of the diagram below Be aware that the air flow sensor is directional L Length of pipe section At inlet L1 15 x inner pipediameter At outlet L2 5 x inner pipe diameter D Inner diamet...

Страница 23: ...39 69 Oxygen O2 176 4 578 74 Nitrous oxide N2O 181 4 595 14 Natural gas NG 109 4 358 92 DIN 1343 0 C 1013 25mbar Maintenance The sensor head should be checked regularly for dirt and cleaned if necessa...

Страница 24: ...slave 2 1 EDR enhanced data rate Bluetooth range 10 meters 33 feet The effective range varies due to propagation conditions material coverage production sample variations antenna configurations and b...