Section VI - Maintenance
NOTICE!
Make sure all seperator elememts are assembled in the correct position. An arrow is
printed on the cover of the seperator elements and the bottom of the shield; all arrows
should be pointing in the same direction after assembly.
• Slide the cover (1) of the oil separator tank back in position. Caution not to squeeze
the O-ring.
• Tighten bolts.
Pressure switch
Testing
CAUTION!
The pressure switch test can only be performed by authorized personnel and is
protected by a security code.
Refer to Airlogic Graphic controller, Test menu.
If the pressure switch does not open at the set pressure of 1500mbar(a), it needs to be
replaced.
Warning
WARNING!
No adjustments are allowed. Never run the vacuum pump without pressure switch.
Quincy Vacuum Pump-QSV Series
85