Section II - General Description
S3
Emergency stop button
1
Electric cabinet
VC
Vacuum control valve
IC
Inlet connection
BV
Thermostatic bypass valve
DC
Discharge connection
CE
Cable entry
Flow diagram
Air flow
Air comes in through air intake filter (AF) and Vacuum Control Valve (VC) and is displaced
by the vacuum pump element (E).
A mixture of air and oil flows into the oil separator tank (OT).
After passing the air/oil separator filter, clean air, conditioned to a few parts per million, is
discharged through the outlet.
Oil system
Quincy Vacuum Pump-QSV Series
11