Section V - Operating Instructions
• Take care that no dirt drops into the oil system.
• Provide labels, warning the operator that:
• The vacuum pump may automatically restart after voltage failure (if activated,
consult Quincy).
• The vacuum pump is automatically controlled and may be restarted automatically.
• The vacuum pump may be remotely controlled.
• Check the programmed settings. Consult section Programmable settings.
• Close the isolation valve.
• Start and run the vacuum pump for a few minutes. Check that the vacuum pump
operates normally.
• Open the inlet isolation valve (IV).
Starting
Figure 7 Control panel Airlogic Graphic
Step
Action
1
Switch on the voltage. Check that voltage on LED (8) lights up.
2
Press start button (14) on the control panel. The vacuum pump starts running and the
automatic operation LED (7) lights up.
3
Open the inlet isolation valve (IV).