Appendix B - Technical Data
80
Quincy Compressor-QSI
®
QSI 600
¯
¯
¯
¯
¯
S
TANDARD
°
°
°
°
°
Full Load Operating Pressure
psig
100
110
125
150
Maximum Operating Pressure
psig
115
125
140
165
Minimum Operating Pressure
psig
Æ
Æ
75
Å
Å
Maximum Ambient Operating Temperature:
Less Cabinet
°F
Æ
Æ
118
Å
Å
With Cabinet
°F
Æ
Æ
110
Å
Å
Minimum Ambient Operating Temperature
°F
Æ
Æ
35
Å
Å
Compressor Drive Motor
HP
Æ
125
150
Å
Rotor Diameter
mm
Æ
Æ
255
Å
Å
Male Rotor Speed
rpm
Æ
1785
1790
Å
Female Rotor Speed
rpm
Æ
1190
1193
Å
Rotor Tip Speed
m/sec.
Æ
23.83
23.9
Å
Inlet Capacity
acfm
630
623
615
594
Displacement at Operating Speed
cfm
*data not available*
Volumetric Efficiency
%
*data not available*
Aftercooling
Heat Rejection:
Fluid Cooler
BTU/min.
4674
4911
5292
5972
Aftercooler
BTU/min.
1016
1018
1017
1025
Aftercooler Approach (standard conditions)
°F
Æ
Æ
6
Å
Å
Maximum Allowable Static Backpressure
in./H
2
O
Æ
Æ
0.125
Å
Å
Fan Motor
HP
Æ
Æ
5
Å
Å
Fan Motor
rpm
Æ
Æ
1790
Å
Å
Fan Flow
cfm
Æ
Æ
12200
Å
Å
Water-cooled Cooling
Recommended Inlet Water Pressure
psig
Æ
Æ
40-100
Å
Å
Vent Fan Motor
HP
Æ
Æ
1/9
Å
Å
Aftercooler Approach to Cooling:
Water Temperature
°F
Æ
Æ
9-10
Å
Å
Water Flow less Aftercooler at: 50°F
gpm
*data not available*
70°F
gpm
15
16
17
38
90°F
gpm
25
27
55
38
Water Flow with Aftercooler at: 50°F
gpm
*data not available*
70°F
gpm
12
14
16
27
90°F
gpm
21
24
45
29
Compressor Fluid
Total Fluid Capacity
gallons
Æ
Æ
13
Å
Å
Reservoir Fluid Capacity
gallons
Æ
Æ
11.8
Å
Å
Fluid Flow
gpm
Æ
Æ
35
Å
Å
Typical Fluid Carryover
ppm
Æ
Æ
1-3
Å
Å
Normal Airend Discharge Temperature
°F
Æ
Æ
190-195
Å
Å
Sound (at 1 meter)
Unenclosed (AC/WC)
dB(A)
Æ
Æ
87/86
Å
Å
Standard Cabinet (AC/WC)
dB(A)
Æ
Æ
82/81
Å
Å
Low Sound Cabinet (AC)
dB(A)
*data not available*
Содержание QSI 1000
Страница 2: ......
Страница 7: ...This page intentionally left blank ...
Страница 11: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION ...
Страница 25: ...Quincy Compressor QSI 19 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 65: ...Quincy Compressor QSI 59 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 66: ...Appendix A Dimensional Drawings 60 Quincy Compressor QSI QSI 220 245 air cooled ...
Страница 67: ...Appendix A Dimensional Drawings Quincy Compressor QSI 61 QSI 220 245 water cooled ...
Страница 68: ...Appendix A Dimensional Drawings 62 Quincy Compressor QSI QSI 250 300 air cooled ...
Страница 69: ...Appendix A Dimensional Drawings Quincy Compressor QSI 63 QSI 250 300 water cooled ...
Страница 70: ...Appendix A Dimensional Drawings 64 Quincy Compressor QSI QSI 335 370 air cooled ...
Страница 71: ...Appendix A Dimensional Drawings Quincy Compressor QSI 65 QSI 335 370 water cooled ...
Страница 72: ...Appendix A Dimensional Drawings 66 Quincy Compressor QSI QSI 440 500 air cooled ...
Страница 73: ...Appendix A Dimensional Drawings Quincy Compressor QSI 67 QSI 440 500 water cooled ...
Страница 74: ...Appendix A Dimensional Drawings 68 Quincy Compressor QSI QSI 540 600 air cooled ...
Страница 75: ...Appendix A Dimensional Drawings Quincy Compressor QSI 69 QSI 540 600 water cooled ...
Страница 76: ...Appendix A Dimensional Drawings 70 Quincy Compressor QSI QSI 675 750 air cooled ...
Страница 77: ...Appendix A Dimensional Drawings Quincy Compressor QSI 71 QSI 675 750 water cooled ...
Страница 78: ...Appendix A Dimensional Drawings 72 Quincy Compressor QSI QSI 925 1000 air cooled ...
Страница 79: ...Appendix A Dimensional Drawings Quincy Compressor QSI 73 QSI 925 1000 water cooled ...
Страница 80: ...Appendix A Dimensional Drawings 74 Quincy Compressor QSI QSI 1175 1250 1400 1500 air cooled ...
Страница 81: ...Appendix A Dimensional Drawings Quincy Compressor QSI 75 QSI 1175 1250 1400 1500 water cooled ...
Страница 99: ......