Section VI - Servicing
20
Quincy Compressor-QSI
®
• Safety
• Water Removal
• Air/Fluid Separator Element
• Fluid Scavenging System
• Air Filter
• Control Line Air Filter
• Shaft Seal
• Air and Fluid Tubing
• O-ring Fittings
Safety
NOTICE!
Maintenance should be performed by trained and
qualified technicians only.
Safety procedures while servicing the compressor are
important to both the service personnel and to those who
may be around the compressor and the system it serves.
Listed below are some, but not all, procedures that should
be followed:
• Wait for the unit to cool before starting service.
Temperatures may exceed 180°F when the
compressor is operating.
• Clean up fluid spills immediately to prevent slipping.
• Loosen, but do not remove, flange or component
bolts. Carefully pry apart to be sure there is no
residual pressure before removing bolts.
• Never use a flammable solvent such as gasoline or
kerosene for cleaning air filters or compressor parts.
• Safety solvents are available and should be used in
accordance with their instructions.
CAUTION!
Unusual noise or vibration indicates a problem.
Do not operate the compressor until the source
has been identified and corrected.
Water Removal
Water vapor may condense in the reservoir and must be
removed. The frequency with which water must be
removed is determined by the ambient air conditions.
During hot and humid conditions, water should be
drained off the bottom of the reservoir daily. In cold and
dry conditions, water may only need to be drained
weekly. To drain water from the reservoir, turn the
compressor off and let sit for at least 5 minutes. Then
open the drain valve. Water is heavier than the
compressor fluid and will collect at the bottom of the
reservoir. When the drain is first opened some
compressor fluid may come out before the water starts to
flow. Close the valve when the water flow changes to
compressor fluid. Make certain that there is no pressure
in the reservoir before opening the drain valve. Water
content in the compressor fluid in excess of 200 PPM
could cause bearing damage and airend failure.
Air/Fluid Separator Element
The separator element is a one piece construction that
coalesces the fluid mist, passing through the filtering
media, into droplets that fall to the bottom of the
separator element to be picked up by a scavenging tube
and returned to the compressor. Use care when handling
the separator element to prevent it from being damaged.
Denting may destroy the effectiveness of the filtering
media and result in excessive fluid carryover. Even a
very small hole punctured through the element will result
in a high fluid carryover. Larger models use two air/fluid
separator elements.
Содержание QSI 1000
Страница 2: ......
Страница 7: ...This page intentionally left blank ...
Страница 11: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION ...
Страница 25: ...Quincy Compressor QSI 19 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 65: ...Quincy Compressor QSI 59 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 66: ...Appendix A Dimensional Drawings 60 Quincy Compressor QSI QSI 220 245 air cooled ...
Страница 67: ...Appendix A Dimensional Drawings Quincy Compressor QSI 61 QSI 220 245 water cooled ...
Страница 68: ...Appendix A Dimensional Drawings 62 Quincy Compressor QSI QSI 250 300 air cooled ...
Страница 69: ...Appendix A Dimensional Drawings Quincy Compressor QSI 63 QSI 250 300 water cooled ...
Страница 70: ...Appendix A Dimensional Drawings 64 Quincy Compressor QSI QSI 335 370 air cooled ...
Страница 71: ...Appendix A Dimensional Drawings Quincy Compressor QSI 65 QSI 335 370 water cooled ...
Страница 72: ...Appendix A Dimensional Drawings 66 Quincy Compressor QSI QSI 440 500 air cooled ...
Страница 73: ...Appendix A Dimensional Drawings Quincy Compressor QSI 67 QSI 440 500 water cooled ...
Страница 74: ...Appendix A Dimensional Drawings 68 Quincy Compressor QSI QSI 540 600 air cooled ...
Страница 75: ...Appendix A Dimensional Drawings Quincy Compressor QSI 69 QSI 540 600 water cooled ...
Страница 76: ...Appendix A Dimensional Drawings 70 Quincy Compressor QSI QSI 675 750 air cooled ...
Страница 77: ...Appendix A Dimensional Drawings Quincy Compressor QSI 71 QSI 675 750 water cooled ...
Страница 78: ...Appendix A Dimensional Drawings 72 Quincy Compressor QSI QSI 925 1000 air cooled ...
Страница 79: ...Appendix A Dimensional Drawings Quincy Compressor QSI 73 QSI 925 1000 water cooled ...
Страница 80: ...Appendix A Dimensional Drawings 74 Quincy Compressor QSI QSI 1175 1250 1400 1500 air cooled ...
Страница 81: ...Appendix A Dimensional Drawings Quincy Compressor QSI 75 QSI 1175 1250 1400 1500 water cooled ...
Страница 99: ......