Section VI - Servicing
Quincy Compressor-QSI
®
21
WARNING!
Do not remove the staples from the separator
element. Their function is to prevent an
electrostatic build-up which could spark a fire.
Use genuine Quincy replacement separators.
Continuity Testing of Separator Elements
NOTICE!
Electrical continuity between all separator
element metal surfaces must be checked prior to
replacing any separator element. Do not install
if continuity is not present. Return the separator
element to your Quincy Distributor for
replacement.
Prior to installation, test the separator element as follows:
1) Locate a continuity test light or a volt-ohm-meter
(v-o-m) capable of reading 20 ohms.
2) Assure that battery has proper charge. Touch the
probe leads together to assure the light works or to
zero calibrate the meter.
3) Contact the grounding staple on the separator
element gasket with the ground probe of the test
indicator.
4) Touch the top cap of the separator element with the
other probe. The indicator light should illuminate
on the test or the v-o-m test must read no more than
20 ohms.
5) Touch the bottom cap of the separator element. The
indicator light should illuminate on the test or the v-
o-m test must read no more than 20 ohms.
6) Touch the outside wire mesh. The indicator light
should illuminate on the test or the v-o-m test must
read no more than 20 ohms.
7) Touch the inside wire mesh ( do not puncture the
element media). The indicator light should
illuminate on the test or the v-o-m test must read no
more than 20 ohms.
8) If the separator element has a gasket on each side of
the flange, repeat steps 3 through 7.
9) If the separator element fails any of the above test ,
return it to your Quincy Distributor for replacement.
10) Make sure the compressor is bonded (wired) to an
earth ground to dissipate static electricity.
Содержание QSI 1000
Страница 2: ......
Страница 7: ...This page intentionally left blank ...
Страница 11: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION ...
Страница 25: ...Quincy Compressor QSI 19 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 65: ...Quincy Compressor QSI 59 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 66: ...Appendix A Dimensional Drawings 60 Quincy Compressor QSI QSI 220 245 air cooled ...
Страница 67: ...Appendix A Dimensional Drawings Quincy Compressor QSI 61 QSI 220 245 water cooled ...
Страница 68: ...Appendix A Dimensional Drawings 62 Quincy Compressor QSI QSI 250 300 air cooled ...
Страница 69: ...Appendix A Dimensional Drawings Quincy Compressor QSI 63 QSI 250 300 water cooled ...
Страница 70: ...Appendix A Dimensional Drawings 64 Quincy Compressor QSI QSI 335 370 air cooled ...
Страница 71: ...Appendix A Dimensional Drawings Quincy Compressor QSI 65 QSI 335 370 water cooled ...
Страница 72: ...Appendix A Dimensional Drawings 66 Quincy Compressor QSI QSI 440 500 air cooled ...
Страница 73: ...Appendix A Dimensional Drawings Quincy Compressor QSI 67 QSI 440 500 water cooled ...
Страница 74: ...Appendix A Dimensional Drawings 68 Quincy Compressor QSI QSI 540 600 air cooled ...
Страница 75: ...Appendix A Dimensional Drawings Quincy Compressor QSI 69 QSI 540 600 water cooled ...
Страница 76: ...Appendix A Dimensional Drawings 70 Quincy Compressor QSI QSI 675 750 air cooled ...
Страница 77: ...Appendix A Dimensional Drawings Quincy Compressor QSI 71 QSI 675 750 water cooled ...
Страница 78: ...Appendix A Dimensional Drawings 72 Quincy Compressor QSI QSI 925 1000 air cooled ...
Страница 79: ...Appendix A Dimensional Drawings Quincy Compressor QSI 73 QSI 925 1000 water cooled ...
Страница 80: ...Appendix A Dimensional Drawings 74 Quincy Compressor QSI QSI 1175 1250 1400 1500 air cooled ...
Страница 81: ...Appendix A Dimensional Drawings Quincy Compressor QSI 75 QSI 1175 1250 1400 1500 water cooled ...
Страница 99: ......