Section VII - Compressor Fluids
36
Quincy Compressor-QSI
®
Converting to QuinSyn PG
Normal Machines
Flush clean machines presently using QuinSyn or
QuinSyn IV before converting them to QuinSyn PG.
Drain compressor thoroughly while hot, including all the
low areas, fluid lines and fluid cooler. Fill with QuinSyn
Flush and run compressor until it reaches normal
operating temperatures. Shut down and lockout the
machine. Drain all the QuinSyn Flush and discard in
accordance with all local, state and federal disposal
regulations. Change the separator and all the filters on
the compressor. Refill the reservoir and system with a
full charge of QuinSyn PG.
NOTICE!
If all the previous fluid is not removed from the
compressor, excessive foam may be visible in the
fluid level sightglass. If this occurs, repeat the
flushing procedure.
Varnished Machines
Flush varnished machines presently using QuinSyn or
QuinSyn IV before converting them to QuinSyn PG.
Drain compressor thoroughly while hot, including all the
low areas, fluid lines and the fluid cooler. Fill with
QuinSyn Flush and run for 300 hours. Take a fluid
sample and send to Quincy Compressor Fluid Analysis to
determine if further flushing is needed. Continue
operating compressor until the results of fluid analysis
are known. Drain or continue to run compressor as
advised by the fluid analysis report.
NOTICE!
More than one flush may be required to remove
varnish build-up and reduce the TAN to an
acceptable level. It may be necessary to change
the fluid filter more frequently while the machine
is being cleaned.
If advised to refill with another charge of QuinSyn Flush,
run compressor until it reaches normal operating
temperature. Shut down and lockout the machine. Drain
all of the original charge of the QuinSyn Flush and
discard in accordance with all local, state and federal
disposal regulations. Refill with a fresh charge of
QuinSyn Flush and change the fluid filters. Run
compressor for 300 hours. Take a fluid sample and send
to Quincy Compressor Fluid Analysis to determine if
further flushing is needed. Proceed as instructed by the
fluid analysis report.
If advised to drain the QuinSyn Flush, run compressor
until it reaches normal operating temperature. Shut down
and lockout the machine. Drain the QuinSyn Flush and
discard in accordance with all local, state and federal
disposal regulations. Change the separator and fluid
filters on the compressor and refill with a full charge of
the QuinSyn PG.
Содержание QSI 1000
Страница 2: ......
Страница 7: ...This page intentionally left blank ...
Страница 11: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION ...
Страница 25: ...Quincy Compressor QSI 19 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 65: ...Quincy Compressor QSI 59 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 66: ...Appendix A Dimensional Drawings 60 Quincy Compressor QSI QSI 220 245 air cooled ...
Страница 67: ...Appendix A Dimensional Drawings Quincy Compressor QSI 61 QSI 220 245 water cooled ...
Страница 68: ...Appendix A Dimensional Drawings 62 Quincy Compressor QSI QSI 250 300 air cooled ...
Страница 69: ...Appendix A Dimensional Drawings Quincy Compressor QSI 63 QSI 250 300 water cooled ...
Страница 70: ...Appendix A Dimensional Drawings 64 Quincy Compressor QSI QSI 335 370 air cooled ...
Страница 71: ...Appendix A Dimensional Drawings Quincy Compressor QSI 65 QSI 335 370 water cooled ...
Страница 72: ...Appendix A Dimensional Drawings 66 Quincy Compressor QSI QSI 440 500 air cooled ...
Страница 73: ...Appendix A Dimensional Drawings Quincy Compressor QSI 67 QSI 440 500 water cooled ...
Страница 74: ...Appendix A Dimensional Drawings 68 Quincy Compressor QSI QSI 540 600 air cooled ...
Страница 75: ...Appendix A Dimensional Drawings Quincy Compressor QSI 69 QSI 540 600 water cooled ...
Страница 76: ...Appendix A Dimensional Drawings 70 Quincy Compressor QSI QSI 675 750 air cooled ...
Страница 77: ...Appendix A Dimensional Drawings Quincy Compressor QSI 71 QSI 675 750 water cooled ...
Страница 78: ...Appendix A Dimensional Drawings 72 Quincy Compressor QSI QSI 925 1000 air cooled ...
Страница 79: ...Appendix A Dimensional Drawings Quincy Compressor QSI 73 QSI 925 1000 water cooled ...
Страница 80: ...Appendix A Dimensional Drawings 74 Quincy Compressor QSI QSI 1175 1250 1400 1500 air cooled ...
Страница 81: ...Appendix A Dimensional Drawings Quincy Compressor QSI 75 QSI 1175 1250 1400 1500 water cooled ...
Страница 99: ......