Never use a high pressure water jet to clean the compressor.
Instructions for air-cooled compressors
1. Stop the compressor, close the air outlet valve and switch off the voltage.
2. Remove any dirt from the coolers with a fibre brush. Never use a wire brush or metal
objects.
3. Cover all parts under the coolers.
4. Next, clean with an air jet in the reverse direction to normal flow. Use low pressure air. If
necessary, the pressure may be increased up to 6 bar(e) (87 psig).
7.5
Filtering panel
Cleaning the filtering panel
Before carrying out any operation on the machine, ensure that the electric power supply
has been disconnected.
• Stop the compressor.
Close the air outlet valve and switch off the voltage.
• Remove the air inlet filter panel(s) (FP1) and the cubicle filter (FP2).
• Clean the inlet filtering panel with a jet of air wash it with water, do not use solvents.
• Replace the cubicle filter.
• Once the operation has been completed, reassemble the filter panel.
Instruction book
82
2920 7101 24
Содержание QGS 90
Страница 2: ......
Страница 19: ...Electric cubicle Y D typical example Instruction book 2920 7101 24 17...
Страница 21: ...The drawings are on the USB supplied with your machine Instruction book 2920 7101 24 19...
Страница 132: ......
Страница 133: ......
Страница 134: ...No 2920 7101 24 2021 08 Printed in Belgium Performance You Demand Reliability You Trust www quincycompressor com...