6. Remove the plug and add oil until the level reaches the filler opening.
7. Fit and tighten the plug (FC).
8. Unlock the emergency stop button and press the "Reset key" on the controller before
restarting.
5.5
Stopping
Controller
Airlogic² control panel
Procedure
Step
Action
-
Press the stop button (11). Automatic operation LED (3) goes out and the compressor stops
after 30 seconds of unloaded operation.
-
To stop the compressor in the event of an emergency,
press the emergency stop button.
Alarm LED (5) flashes.
• Remedy the problem cause and unlock the button by pulling it out.
• Navigate to the Stop icon on the display by means of the navigation keys (12) and press
the Select key.
Press reset.
Do not use emergency stop button for normal stopping!
-
Close the air outlet valve (AV).
-
Press the test button on the top of the electronic water drain(s) until the air system between
the air system receiver and the outlet valve is fully depressurized. See section
.
Switch off the voltage.
-
If available, open the condensate drain valve of the compressor (Dm) to drain the water trap
completely.
Instruction book
2920 7101 24
73
Содержание QGS 90
Страница 2: ......
Страница 19: ...Electric cubicle Y D typical example Instruction book 2920 7101 24 17...
Страница 21: ...The drawings are on the USB supplied with your machine Instruction book 2920 7101 24 19...
Страница 132: ......
Страница 133: ......
Страница 134: ...No 2920 7101 24 2021 08 Printed in Belgium Performance You Demand Reliability You Trust www quincycompressor com...