background image

Installation Instruction

2

Index

Automatism installation preparation..........................................................   pag.    4

Automatism description ..............................................................................   pag.    4 

Sizes and dimensions ........................................................................................   pag.     5

Automatism assembly  ................................................................................................. pag.       6

Adjustment of the stop .............................................................................................. pag.

10

Battery connections .................................................................................................... pag.

10

Final operations ............................................................................................................ pag.

10

Power connections ....................................................................................................... pag.

10

Electrical connections................................................................................................... pag.

10

Number wing selection............................................................................................... pag.

11

Single wing Multislave selection ........................................................................... pag.

11

Double wing Master - Slave selection .................................................................. pag.

11

“Low Power” mode selection ................................................................................... pag.

11

First input mode selection ....................................................................................... pag.

12

Antipanic mode selection .......................................................................................... pag.

12

Electric Lock selection ................................................................................................ pag.

12

Logic right / left opening sense ............................................................................. pag.

12

Type of arm selection ................................................................................................. pag.

13

SWINGY  electronic board........................................................................................ pag.

13

Connections .................................................................................................................. pag.

13

Led functions ............................................................................................................... pag.

15

Jumpers .......................................................................................................................... pag.

15

Start up - Operating logic  ...................................................................................... pag.

16

Error Message Table..................................................................................................... pag.

17

Double SWINGY  connection and use ............................................................... pag.

18

Inter lock connection and use ............................................................................... pag.

18

Delivery modality  ....................................................................................................... pag.

18

   4

Dimensions of the fixing holes and cables opening .......................................    pag.      5

QKSW80

Содержание Swingy QK-SW80

Страница 1: ... QK SW80 USER MANUAL V01_2011 ...

Страница 2: ...pag 11 Double wing Master Slave selection pag 11 Low Power mode selection pag 11 First input mode selection pag 12 Antipanic mode selection pag 12 Electric Lock selection pag 12 Logic right left opening sense pag 12 Type of arm selection pag 13 SWINGY electronic board pag 13 Connections pag 13 Led functions pag 15 Jumpers pag 15 Start up Operating logic pag 16 Error Message Table pag 17 Double SWI...

Страница 3: ...ame All automatic entrance safety and protection devices photocells active sensors etc must be installed in accordance with the regulations and directives in force forces and inertia in play Pay careful attention to area where the following may occur crushing cutting conveyance and any other type of hazard in general applying if necessary tion information on every installation Make sure that the u...

Страница 4: ...up of A Steel fastening base B Plastic cover C Gear motor unit D Electronic control panel E Transformer F Emergency battery 12V 1 3Ah G Encoder unit H Switch Installation Instruction 4 Fig 1 Fig 2 Power supply 230V ac 50 Hz Nominal power 60 W Nominal motor torque 35 Nm External device power 12Vdc 2 5W Emergency battery 12 V 1 3 Ah Max opening angle 100 Wing maximum weight 80 Kg Wing dimensions 700...

Страница 5: ...with the product to make easier the installation Fig 4 440 311 65 87 47 9 153 269 76 94 9 Dimension of the fixing holes and cables opening SWINGY standard In case of double SWINGY provide to the predisposition of the connection cables passing between the two operators QK SW80 ...

Страница 6: ...wings anticlockwise direc tion the assembly of the automatism perfectly mir rors the left hand opening assembly Rigid pull arm Aluminium guide Gearmotor Axis OPENING DIRECTION Fig 6 WARNING The final tighte ning of the screws must be perfor med only after having checked that the vertical positioning of the automatism guarantees a good parallelism between the hinge axis and the gearmotor axis For t...

Страница 7: ...nsions articulated push arm QK SW80PUSH The articulated push arm is used when the automatism is installed on the approach side of the door the side opposite the swing side WARNING For a correct positioning always use the main axis of the wing hinges and the operation axis of the gear motor as a reference as shown in Fig 7 WARNING The final tightening of the screws must be performed only after havi...

Страница 8: ...on ding to the V impression on the guide profile Use the holes to fix the guide to the frame using the appropriate screws Fig 11 Part C Insert the cylindrical slide Fig 11 Part D complete with the relative spindle inside the guide and distribute a uniform layer of grease over the sliding zone Then after finishing the installation of the rigid arm Fig 11 Part E screw the threaded shaft inserted in ...

Страница 9: ...es Insert the bracket of the arm Fig 13 part A in the appropriate seat on the gearmotor and fix it using the two countersunk head screws provi ded Carefully check that the upper part of the articulated arm rotates easily under the frame of the wing Fig 7 8 and 9 Drill the frame at the positions indicated in Fig 7 and fix the wing attach ment of the articulated arm to the frame using the appropriat...

Страница 10: ...st or shavings Ensure the proper fixing of the automatism on the wall Check correct tightening Check that the wires are fixed and that no wire pass near the carriage sliding area Check that the arm is solidly fixed to the wing and that it is equipped with the appropriate stop to limit the max opening angle to 100 Electrical connections WARNING All board or peripheral connections on the terminal bo...

Страница 11: ...al mode S1 ON S2 ON S3 ON Enter double Master door If asynchronous it is the first to open and the last to close S1 OFF S2 ON S3 ON Enter double Slave door If asynchronous it is the last to open and the first to close Synchronised door motion Asynchronous door motion A single selector can be connected and extended to several SWINGY automatisms using two different operation logics DEFAULT the selec...

Страница 12: ...or S6 OFF DEFAULT Antipanic mode disabled In the event of power failure the equipment continues working powered by the battery Logic right left opening sense S8 ON Wing Left Opening rigid pull arm Wing Right Opening articulated push arm S8 OFF DEFAULT Wing Right Opening rigid pull arm Wing Left Opening articulated push arm Wing Left Opening rigid pull arm Wing Right Opening articulated push arm Wi...

Страница 13: ... led D33 is on it indicates normal voltage presence 12V If off check For mains and or battery voltage BASE SELECTOR Shielded cable with 4 wires 0 22 mm Do not con nect the shield of the wire used Fig 19 Type of arm selection J13 ON ARTICULATED PUSH ARM Wing Left Opening or Wing Right Opening J13 OFF DEFAULT RIGID PULL ARM Wing Left Opening or Wing Right Opening In order to optimize the operation o...

Страница 14: ...n the set condition Reset open closed etc SAFE OPEN NA Signal for the connection of sensors for protec tion during wing opening If the door is opening and the contact closes the unit sends an immedi ate movement stop command Opening will only continue after this sig nal is deactivated KEY NC Lock signal Closure devices can be con nected such as electronic key key selec tor transponder etc The sign...

Страница 15: ...ripheral power supply Fig 22 Diagnostics Led see Error Message Table External peripheral signal presence led LED Functions Jumpers Jumper ON OFF Default J13 Articulated arm Rigid pull arm J11 Set cycle operations Normal operation J12 Set properly the jumper J13 look at the arm typology paragraph QK SW80 ...

Страница 16: ...ons without connections to the open command device use the START button on the unit see Fig 17 Standard manoeuvre The device opens and closes the door accelerating and decelerating in accordance with the opening and closing speed limits which will be reached at low speed Push Go An initial push on a closed door will cause it to open Reverse function radar 1 and 2 If the radar detects an obstacle w...

Страница 17: ...se it again at normal speed After detecting the third obstacle without being able to complete the manoeuvre without completely opening the door the device signals a malfunction AV intermittent and L1 On stops for a few seconds whilst closing and then performs a new reset to set the ends of stroke If the object remains in the movement area it will be detected as the end of stroke and the device wil...

Страница 18: ...same way as with single devices If it is detected that one of the devices is trying to open a door this will cause both doors to open The anti crush safety devices and obstacle detection functions are controlled separately and independently by both cards If one card detects an anti crush device whilst closing it will stop the motion of both doors and open them completely at low speed If one card d...