5
E
N
G
L
I
S
H
FIG. 4
6- POSITIONING THE LIMIT SWITCHES BRACKETS (CAMMES)
FIG. 5
Manually position the gate completely open and fasten the limit switch brackets (1) (2) onto the rack so that
the limit switch lever exceeds the length of the brackets by approximately two/thirds. Repeat the operation
with gate completely closed. Provide power and carry out some opening and closing operations (see control
board user manual). Adjust the limit switch brackets so that the gate stops approximately 20 mm before the
opening and closing stops.
Содержание MOOVY QK-M1200
Страница 4: ...4 FIG 3 ...
Страница 10: ...11 E N G L I S H ...
Страница 11: ...m ...
Страница 15: ...16 FIG 3 ...
Страница 21: ...23 I T A L I A N O ...