16
EN
TCD1044 E - REV003A
ELECTRICAL CONNECTIONS DIAGRAM
ELECTRIC CONNECTIONS
The remote control complies with EMC standards (electromagnetic compatibility) but requires correct installation to avoid com-
promising its performance and that of the surronding instruments.
For this reason the remote control wires must be positioned at a distance of at least:
• 1 m away from cables that carry radio signals (except SSB radio transmitters).
• 2 m away from cables for SSB radio transmitter signals.
Follow the rules below to construct the electrical installation relative of the remote control:
• Connect the remote control connectors to the connectors coming from the thrusters.
• Put in a switch, to turn on and shut off the remote control (not provided).
• Position the switch so that it is within easy reach should it be necessary to shut off the remote control in an emergency.
• Insert a 8A quick-acting fuse on the remote control power supply line (not provided).
• Use wires, for the remote control power supply, with a correct cross section according to their length.
• Do not use supply from the motors or thrusters battery circuit for the remote control.
• Before switching on the power to the remote control, check that all the electrical connections are correct.
INSTALLATION
THRUSTERS
BATTERY
RED
BLACK
MOTOR
SERVICE
BATTERY
BATTERY
ISOLATOR
SWITCH
FUSE
*
*
* Common negative for the battery groups.
FUSE
MOTOR
BATTERY
ISOLATOR
FUSE
BOW THRUSTER
STERN THRUSTER
CONTROL CABLE
EXTENSIONS
(OPTIONALS)
Содержание THRUSTERS COMMAND