5. Maintenance
This electrolysis equipment does not require any specific maintenance while the cell is within its
useful life. However, here are some tips that will help you to function optimally and prolong the
life of your cell:
Make a periodic overview of the equipment: Note that the cables are in good condition, free of
rust and other damage.
If you have an automatic pH regulation system, never place the acid tank under the equipment,
and make sure that it is well covered.
Caution:
extreme precautions if you have to handle acid. Use appropriate
protective equipment (goggles, mask, gloves).
Avoid using the equipment with too low salt concentrations.
The performance of the cell
decreases, and so does the life of the cell. Check the salt concentration regularly. In any case, the
equipment will inform you of a low concentration if it occurs.
Make a periodic visual check of the cell,
especially the space between the electrodes. There is no
need to dismantle it, just check through the cup for incrustations. If that happens, you may need to
adjust the self-cleaning system to a higher frequency (decrease the time between cleanings).
When the cell has reached its useful life, you will notice that the equipment shows a lack of salt
warning, and the production is limited to low percentages. If you are confident that the salt levels are
adequate, the cell may be exhausted.
Other reasons why your
QUICKSALT
equipment may show a warning for lack of salt:
- Very low water temperature
- Incrustations between electrodes.
In case of incrustations, decrease the time between cleanings. If that is not enough to remove them, it
should be dismantled and cleaned with 10
%
dilute muriatic acid.
It is recommended not to use the electrolysis equipment in low water temperatures below 50 F
(10
º
C), as cell life is reduced in these conditions. Please, switch off or select the “stand-by” status
when the temperature is lower than 50
º
F.
With the Temperature Kit (sold separately) the Quicksalt automatically detects the temperature
and displays it on the screen. In cold water conditions bellow 50° F (10
º
C) the Quicksalt
automatically
stops its chlorine output and a warning message will appear on the screen. When
the temperature exceeds 59° F (15
º
C),
5.1. Winterizing