MANUAL DE USUARIO
14
2)
Add Teflon tape to the threads of the flow sensor to ensure proper sealing.
3)
Insert the flow sensor into the collar, threading it in and ensuring that it is mounted so that the
arrow on the sensor marks the correct direction of water flow.
4)
Connect the jack connector from the Flow Switch to its socket, placed on the left side of the unit.
Paddle length
Water flow (Gall/min)
11/2”
2”
*Close
**Open
*Close
**Open
1
60
53
134
112
1+2
45
40
102
85
1+2+3
38
34
85
72
1+2+3+4
29
28
58
53
1+2+3+4+5
19
18
43
40
1+2+3+4+5+6
16
15
40
36
* Close by flow rise
** Open by flow decrease
Note:
An excessively long paddle in a high water flow would reduce the life of
the sensor. On the other hand, a too short blade at a too low flow rate would
not allow the correct detection of the flow rate.
Note:
Before proceeding with the electrical installation, we suggest that you
check that the hydraulic installation has been done correctly and that there are
no leaks or drips. To do this, open the valves in your system again, move the
selector valve to the “filtration” position and start the pump. If you do not see a
problem, continue with the next section.