8
04.10.2021
20210927 QC-PC-PID-01-Bedienungsanleitung engl.
MONITOR-menu
The
MONITOR
-menu controls the process.
The
MONITOR
-menu shows all important values for controlling the control process.
Function Keys:
jumps to the software version menu
jumps to the
SETPOINT-MENU
jumps into the
PARAMETER-MENU
with password protection
switches off peltier supply resp.
switches on the peltier supply
Display fields:
T-BOARD
shows the temperature of the electronics. The controller has a fan that continuously drives
air through the housing. This cools the electronic components. With sufficient cooling, the board
temperature is highlighted in green. If the colour changes to yellow, the cooling is insufficient. Check
if the fan is running. Check also the load current and the free air supply. If the board temperature
exceeds a critical value, the colour changes to red and the control switches off. The controller can
only be restarted when the board temperature has returned to the green area.
TARGET TEMPE
shows the target value for the temperature
PM
shows the maximum output voltage as a percentage of the supply voltage
ACTUAL TEMPERATURE
shows the temperature currently measured on the sensor
TEC-CUR
shows the current flow through the connected element
TEC-VOLT
shows the current voltage at the output
TEC-POW
shows the electrical power that is supplied to the connected element
(TEC-POW = TEC-VOLT X TEC-CUR)
Display Function:
Indicates power
supply to the
consumer is OFF
Key Function:
Tap to Turn ON the
power supply to the
consumer
Display Function:
Indicates power
supply to the
consumer is ON
Key Function:
Tap to Turn OFF the
power supply to the
consumer
Dual function:
Operation indicator light & Switch ON/OFF