6
QUEST 100
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
QUESTCLIMATE.COM
(877) 420-1330
DUCTING TO HVAC OPTIONS
A. HVAC SUPPLY TO SUPPLY
CAUTION!
To avoid the dehumidifier cycling in and out of DEFROST, it is recommended that the leaving air temperature
of the A/C coil is not below 55°F. Also, this install is not recommended for climates where the heating
system will run during the spring and fall times of year, as this could diminish the water removal capability
of the dehumidifier. If the Check Damper is not used, it is important to have the HVAC system fan ON when
the dehumidifier is ON to prevent backflow of air.
WARNING!
Due to pressure resistance it is not recommended to use the optional outdoor air
intake when installing the dehumidifier supply to supply.
B. DEDICATED RETURN TO SUPPLY
Quest 100
Indoor Air
Return
Air Handler Supply
Quest 100 Supply
Optional Duct
Tee & Gravity
Damper
HVAC
Supply
Quest 100
Return
Dry Air to
Conditioned Space
Quest 100
Supply
Air Handler
Optional Check Damper
(No HVAC fan needed)